55464-U
Supel™ QuE QuEChERS tube
PSA/ENVI-Carb Tube 2, pk of 50, suitable for EN 15662:2008 per BS, centrifuge tube volume 15 mL , Shaker Compatible
Synonyma:
QuEChERS
About This Item
Doporučené produkty
product name
Supel™ QuE, PSA/ENVI-Carb Tube 2, pk of 50, suitable for EN 15662:2008 per BS, centrifuge tube volume 15 mL , Shaker Compatible
material
polypropylene tube
agency
suitable for BS EN 15662:2008
product line
Supel™
composition
Magnesium Sulfate, 900 mg
Supelclean™ ENVI-Carb, 45 mg (Cat. No. 57210-U)
Supelclean™ PSA, 150 mg (Cat. No. 52738-U)
packaging
pk of 50
technique(s)
QuEChERS: suitable
centrifuge tube volume
15 mL , Shaker Compatible
matrix active group
PSA phase
carbon phase
application(s)
food and beverages
separation technique
reversed phase
Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů
General description
Using the QuEChERS method, food/agricultural samples are first extracted with an aqueous miscible solvent (e.g., acetonitrile) in the presence of high amounts of salts (e.g., sodium chloride and magnesium sulfate) and/or buffering agents (e.g. citrate) to induce liquid phase separation and stabilize acid and base labile pesticides, respectively. Upon shaking and centrifugation, an aliquot of the organic phase is subjected to further cleanup using SPE. Unlike traditional methods using SPE tubes, in dispersive SPE, cleanup is facilitated by mixing bulk amounts of SPE (e.g., Supelclean PSA, ENVI-Carb, and/or Discovery DSC-18) with the extract. After sample cleanup, the mixture is centrifuged and the resulting supernatant can either be analyzed directly or can be subjected to minor further treatment before analysis.
Supelco carries a line of vials and centrifuge tubes containing pre-determined amounts of salts and SPE sorbents to support the most common method configurations used today.
Compatibility
Suitability
Legal Information
Storage Class
13 - Non Combustible Solids
wgk_germany
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
Vyberte jednu z posledních verzí:
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Sortimentní položky
Reversed-phase interaction will retain most molecules with hydrophobic character; it is very useful for extracting analytes that are very diverse in structure within the same sample.
Související obsah
QuEChERS method simplifies sample cleanup for pesticides analysis in food and agricultural samples.
Metoda QuEChERS zjednodušuje čištění vzorků pro analýzu pesticidů v potravinách a zemědělských vzorcích.
FAS, or 'forever chemicals,' persist in the environment and pose risks to human health. Discover our environmental monitoring tools for PFAS quantification, aiding researchers, regulators, and labs in testing for PFAS.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.