Přejít k obsahu
Merck
Všechny fotografie(1)

Key Documents

MSCAL3

Supelco

ProteoMass Protein MALDI-MS Calibration Kit

Protein MALDI MS Calibration Standard

Synonyma:

Protein Mass Spectrometry Calibrators

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

UNSPSC Code:
12161503
NACRES:
NA.24

product line

ProteoMass

Quality Level

quality

Protein MALDI MS Calibration Standard

application(s)

cleaning products
cosmetics
flavors and fragrances
food and beverages
personal care

storage temp.

15-25°C

Application

This kit features a convenient selection of pre-qualified standard proteins, matrices, and solvents for calibrating and testing matrix assisted laser desorption ionization (MALDI) mass spectrometers. Configured specifically for applications in the mass range of 5 to 66 kDa, MSCAL3 is ideal for most protein studies. Applications include calibration, tuning, and sensitivity testing of MALDI instruments from all manufacturers.
ProteoMass Protein MALDI-MS Calibration Kit has been used as a mass calibration standard for MALDI-TOF MS (matrix assisted laser desorption ionization-time of flight mass spectrometry) analysis.

Legal Information

6538 is a trademark of American Type Culture Collection
ProteoMass is a trademark of Sigma-Aldrich Co. LLC

Pouze součásti soupravy

Č. produktu
Popis

  • Sinapinic acid, Use tested for MALDI-TOF Mass Spec. 8 x 10

Součásti soupravy, které jsou dostupné také samostatně

Č. produktu
Popis
Bezpečností list

  • I6279ProteoMass Insulin MALDI-MS Standard, vial of 10 nmol, monoisotopic mol wt 5,729.6087 Da 2 x 10Bezpečností list

  • C8857ProteoMass Cytochrome c MALDI-MS Standard, vial of 10 nmol, (M+H+) 12,361.96 Da by calculation 2 x 10Bezpečností list

  • A8971ProteoMass Apomyoglobin MALDI-MS Standard, vial of 10 nmol, (M+H+) 16,952.27 Da by calculation 2 x 10Bezpečností list

  • A9096ProteoMass Aldolase MALDI-MS Standard, vial of 10 nmol, average mol wt 39,211.28 Da by calculation 2 x 10Bezpečností list

  • A8471ProteoMass Albumin MALDI-MS Standard, vial of 10 nmol, average mol wt 66,429.09 Da by calculation 2 x 10Bezpečností list

  • Acetonitrile 30 mL

related product

Č. produktu
Popis
Stanovení ceny

pictograms

FlameExclamation mark

signalword

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Respiratory system

Storage Class

3 - Flammable liquids

wgk_germany

WGK 3


Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Wipawadee Sianglum et al.
PloS one, 6(2), e16628-e16628 (2011-02-18)
The ethanolic extract from Rhodomyrtus tomentosa leaf exhibited good antibacterial activities against both methicillin-resistant Staphylococcus aureus (MRSA) and S. aureus ATCC 29213. Its minimal inhibitory concentration (MIC) values ranged from 31.25-62.5 µg/ml, and the minimal bactericidal concentration (MBC) was 250
Binding of the N-terminal domain of the lactococcal bacteriophage TP901-1 CI repressor to its target DNA: a crystallography, small angle scattering, and nuclear magnetic resonance study.
Frandsen KH, et al.
Biochemistry, 52, 6892-6904 (2013)
Expression and purification of recombinant apolipoprotein A-I Zaragoza (L144R) and formation of reconstituted HDL particles.
Fiddyment S, et al.
Protein Expression and Purification, 80, 110-116 (2011)
Marta Martínez-Júlvez et al.
The FEBS journal, 279(23), 4306-4317 (2012-10-09)
The RdxA oxygen-insensitive nitroreductase of the human gastric pathogen Helicobacter pylori is responsible for the susceptibility of this organism to the redox active prodrug metronidazole [2-(2-methyl-5-nitro-1H-imidazol-1-yl)ethanol]. Loss-of-function mutations in rdxA are primarily responsible for resistance to this therapeutic. RdxA exhibits potent
Tyler A Zimmerman et al.
Analytical chemistry, 83(15), 6090-6097 (2011-06-23)
In-source decay (ISD) fragmentation as combined with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry allows protein sequencing directly from mass spectra. Acquisition of MALDI-ISD mass spectra from tissue samples is achieved using an appropriate MALDI matrix, such as 1,5-diaminonaphthalene (DAN). Recent

Související obsah

Discover our wide variety of products for intact mass analysis of monoclonal antibodies, including size-exclusion columns (SEC), ion exchange columns, reverse-phase columns, HPLC buffers, MALDI matrices and standards, high-purity solvents, reagents, tools for protein sample preparation, and certified reference materials.

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.