Přejít k obsahu
Merck
Všechny fotografie(4)

Key Documents

M2004

Sigma-Aldrich

N-Methyl-D-glucamine

99.0-100.5% (titration)

Synonyma:

1-Deoxy-1-(methylamino)-D-glucitol, Meglumine

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Empirický vzorec (Hillův zápis):
C7H17NO5
Číslo CAS:
Molekulová hmotnost:
195.21
Beilstein/REAXYS Number:
385906
EC Number:
MDL number:
UNSPSC Code:
12352104
PubChem Substance ID:
NACRES:
NA.22

assay

99.0-100.5% (titration)

form

powder

autoignition temp.

~662 °F

mp

129-131.5 °C (lit.)

SMILES string

CNC[C@H](O)[C@@H](O)[C@H](O)[C@H](O)CO

InChI

1S/C7H17NO5/c1-8-2-4(10)6(12)7(13)5(11)3-9/h4-13H,2-3H2,1H3/t4-,5+,6+,7+/m0/s1

InChI key

MBBZMMPHUWSWHV-BDVNFPICSA-N

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

General description

N-Methyl-D-glucamine, also known as methylglucamine, is an organic compound that belongs to the class of amino sugars. It is commonly used in pharmaceutical and biochemical applications as a resolving and buffering agent. Salts of N-methyl-D-glucamine have also been used for X-ray contrast media and nuclear imaging agents.

Application

N-Methyl-D-glucamine (NMG) can be used as a reactant to prepare water-soluble polymer for the selective removal of arsenic from aqueous water. It is also used in the development of various resins and gels containing NMG to remove different oxyanions.

Storage Class

11 - Combustible Solids

wgk_germany

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)


Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Raphaëlle Renard-Penna et al.
Radiology, 275(2), 458-468 (2015-01-20)
To compare the diagnostic performance of the magnetic resonance (MR) imaging-based Prostate Imaging Reporting and Data System (PI-RADS) and a Likert scale in the detection of prostate cancer in a cohort of patients undergoing initial prostate biopsy. This institutional review
Philipp Kickingereder et al.
Neuro-oncology, 17(8), 1139-1147 (2015-03-11)
To analyze the relevance of dynamic susceptibility-weighted contrast-enhanced MRI (DSC-MRI) derived relative cerebral blood volume (rCBV) analysis for predicting response to bevacizumab (BEV) in patients with recurrent glioblastoma (rGB). A total of 127 patients diagnosed with rGB receiving either bevacizumab
Vidhya M Ravi et al.
Life science alliance, 2(4) (2019-06-30)
When it comes to the human brain, models that closely mimic in vivo conditions are lacking. Living neuronal tissue is the closest representation of the in vivo human brain outside of a living person. Here, we present a method that
Ntobeko A B Ntusi et al.
JACC. Cardiovascular imaging, 8(5), 526-536 (2015-04-22)
The goal of this study was to assess the diffuse myocardial fibrosis and edema in rheumatoid arthritis (RA) using multiparametric cardiac magnetic resonance (CMR) and the association of myocardial T1 and extracellular volume (ECV) with disease activity, duration, and cardiac
Alexander Radbruch et al.
Radiology, 275(3), 783-791 (2015-04-08)
To compare changes in signal intensity (SI) ratios of the dentate nucleus (DN) and the globus pallidus (GP) to those of other structures on unenhanced T1-weighted magnetic resonance (MR) images between linear and macrocyclic gadolinium-based contrast agents (GBCAs). The study

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.