650463
Dichloromethane
HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%, contains 50-150 ppm amylene as stabilizer
Synonyma:
methylene chloride, Methylene chloride
About This Item
Doporučené produkty
grade
HPLC Plus
for residue analysis
Quality Level
vapor density
2.9 (vs air)
vapor pressure
24.45 psi ( 55 °C)
6.83 psi ( 20 °C)
assay
≥99.9%
form
liquid
autoignition temp.
1223 °F
contains
50-150 ppm amylene as stabilizer
expl. lim.
22 %
technique(s)
HPLC: suitable
gas chromatography (GC): suitable
impurities
≤ 1.0 ppb Fluorescence (quinine) at 365 nm
≤0.01% water
evapn. residue
≤0.0001%
halogenated residue
≤10 ng/L (as heptachlor epoxide)
refractive index
n20/D 1.424 (lit.)
bp
39.8-40 °C (lit.)
mp
−95 °C (lit.)
density
1.325 g/mL at 25 °C (lit.)
λ
H2O reference
UV absorption
λ: 235 nm Amax: 1.0
λ: 240 nm Amax: 0.10
λ: 250 nm Amax: 0.02
λ: 300-400 nm Amax: 0.005
SMILES string
ClCCl
InChI
1S/CH2Cl2/c2-1-3/h1H2
InChI key
YMWUJEATGCHHMB-UHFFFAOYSA-N
Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů
Související kategorie
General description
Application
- Extraction of neonicotinoids from honey samples along with acetonitrile using dispersive liquid-liquid microextraction (DLLME)
- Ultrasonic solvent extraction and clean-up of roasted coffee samples for the analysis of 7 pesticide residues by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
- DLLME based additional pre-concentration of the sample extracts in the analysis of three amphenicols in food products of animal origin by HPLC with UV detection
- Removal of organic phase of the obtained soil sample extracts in the determination of two sulfonylurea herbicides using HPLC
- Testing of four extraction solvents in the development of a HPLC-amperometric detection based method for the analysis of three carbamate residues in liquid and solid food samples
- Extraction of metrafenone from vegetable samples by matrix solid-phase dispersion (MSPD method followed by HPLC analysis
Packaging
Other Notes
Legal Information
signalword
Warning
hcodes
Hazard Classifications
Carc. 2 - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
target_organs
Central nervous system
Storage Class
6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
wgk_germany
WGK 2
flash_point_f
does not flash
flash_point_c
does not flash
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Sortimentní položky
Highly accurate HPLC-FLD method for evaluating 15 PAHs in olive oil using Ascentis® Express PAH HPLC column and SPE cleanup, following GB 5009.265-2021.
Protokoly
In the present study we demonstrate compliance of silica gel 60 F254 HPTLC plates with USP requirements, and how HPTLC plates are suitable for the Sildenafil citrate-Limit of Imidazole test.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.