NIST1951C
Lipids in frozen human serum
NIST® SRM® 1951c
Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen
About This Item
Doporučené produkty
grade
certified reference material
Quality Level
form
liquid
packaging
pkg of 4 vials (2 ea conc)
manufacturer/tradename
NIST®
technique(s)
mass spectrometry (MS): suitable
application(s)
clinical testing
format
matrix material
General description
A unit of SRM1951C consists of four vials of frozen human serum, two vials each at two different analyte concentration levels. Each bottle contains approximately 1 mL of serum.
NIST1951C_Cert
NIST1951C_SDS
NIST1951C_Cert
NIST1951C_SDS
Application
The lipids in frozen human serum are a standard reference material (SRM) that is used for evaluating the accuracy of clinical procedures for the determination of total cholesterol, high-density lipoprotein (HDL)-cholesterol, low-density lipoprotein (LDL)-cholesterol, and total glycerides in human serum. It is also used for validating working or secondary reference materials.
Other Notes
- Details on expiration, storage, safety, usage, and source are provided in the NIST certificate.
- Notes on biomaterials, disposal, and transport are documented in SDS.
Certified for the analytes listed below.
Total Cholesterol, Total Glycerides
Reference/Informational value is provided for the following analytes.
HDL-Cholesterol, LDL-Cholesterol, Total Cholesterol
See certificate for values and more details at nist.gov/SRM.
Total Cholesterol, Total Glycerides
Reference/Informational value is provided for the following analytes.
HDL-Cholesterol, LDL-Cholesterol, Total Cholesterol
See certificate for values and more details at nist.gov/SRM.
Preparation Note
- The serum is shipped frozen on dry ice and after receiving it should be frozen until ready for use.
- Before use, the bottles must be thawed to room temperature.
- The certified concentrations apply only to serum thawed to room temperature, 20 °C to 25 °C.
Legal Information
NIST is a registered trademark of National Institute of Standards and Technology
SRM is a registered trademark of National Institute of Standards and Technology
related product
Č. produktu
Popis
Stanovení ceny
Storage Class
12 - Non Combustible Liquids
wgk_germany
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
Vyberte jednu z posledních verzí:
Osvědčení o analýze (COA)
Je nám líto, ale pro tento produkt momentálně nemáme COA k dispozici online.
Potřebujete-li pomoc, obraťte se na Zákaznická podpora
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Analytical chemistry, 90(20), 11962-11971 (2018-09-14)
We report an extensive 600 MHz NMR trial of quantitative lipoprotein and small-molecule measurements in human blood serum and plasma. Five centers with eleven 600 MHz NMR spectrometers were used to analyze 98 samples including 20 quality controls (QCs), 37
The extended lipid panel assay: a clinicallydeployed high-throughput nuclear magnetic resonance method for the simultaneous measurement of lipids and Apolipoprotein B
Adv. in Lipids Research (2020)
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.