1.02822
Cyclohexane
for spectroscopy Uvasol®
Synonyma:
Hexahydrobenzene, Hexamethylene, Naphthene
About This Item
Doporučené produkty
vapor density
2.9 (vs air)
Quality Level
vapor pressure
168.8 mmHg ( 37.7 °C)
77 mmHg ( 20 °C)
assay
≥99.9% (GC)
form
liquid
autoignition temp.
500 °F
potency
>5000 mg/kg LD50, oral (Rat)
>2000 mg/kg LD50, skin (Rabbit)
expl. lim.
9 %
technique(s)
UV/Vis spectroscopy: suitable
impurities
≤0.0002 meq/g Acidity
≤0.0002 meq/g Alkalinity
≤0.005% Water
evapn. residue
≤0.0002%
color
APHA: ≤10
transmittance
208 nm, ≥20%
220 nm, ≥55%
230 nm, ≥80%
240 nm, ≥90%
250 nm, ≥98%
refractive index
n20/D 1.426 (lit.)
kinematic viscosity
1.26 cSt(20 °C)
bp
80.7 °C (lit.)
mp
4-7 °C (lit.)
transition temp
flash point -18 °C
density
0.779 g/mL at 25 °C (lit.)
UV absorption
λ: 208 nm Amax: ≤0.70
λ: 220 nm Amax: ≤0.26
λ: 230 nm Amax: ≤0.10
λ: 240 nm Amax: ≤0.05
λ: 250 nm Amax: ≤0.01
storage temp.
2-30°C
SMILES string
C1CCCCC1
InChI
1S/C6H12/c1-2-4-6-5-3-1/h1-6H2
InChI key
XDTMQSROBMDMFD-UHFFFAOYSA-N
Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů
General description
Application
- Synthesis and Characterization of Graft Copolymers with Poly(ε-caprolactone) Side Chain Using Hydroxylated Poly(β-myrcene-co-α-methyl styrene).: This article details the synthesis and characterization of novel graft copolymers, which include cyclohexane derivatives, for potential use in drug delivery systems, showcasing their thermal and chemical stability which is crucial for pharmaceutical applications (Li T et al., 2024).
- Direct Extraction and Determination of Free Nicotine in Cigarette Smoke.: This study presents a method for the direct extraction and quantitative analysis of nicotine in cigarette smoke using cyclohexane as a solvent, highlighting its efficiency and safety in analytical chemistry applications (Li L et al., 2024).
Analysis Note
Evaporation residue: ≤ 0.0002 %
Water: ≤ 0.005 %
Colour: ≤ 10 Hazen
Acidity: ≤ 0.0002 meq/g
Alkalinity: ≤ 0.0002 meq/g
Fluorescence (as quinine at 254 nm): ≤ 1.0 ppb
Fluorescence (as quinine at 365 nm): ≤ 1.0 ppb
Transmission (at 208 nm): ≥ 20 %
Transmission (at 220 nm): ≥ 55 %
Transmission (at 230 nm): ≥ 80 %
Transmission (at 240 nm): ≥ 90 %
Transmission (from 250 nm): ≥ 98 %
Absorbance (at 208 nm): ≤ 0.70
Absorbance (at 220 nm): ≤ 0.26
Absorbance (at 230 nm): ≤ 0.10
Absorbance (at 240 nm): ≤ 0.05
Absorbance (from 250 nm): ≤ 0.01
Meet the requirements of "Specific use spectroscopy" according ACS and Reag. Ph Eur
Other Notes
Legal Information
related product
signalword
Danger
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3
target_organs
Central nervous system
Storage Class
3 - Flammable liquids
wgk_germany
WGK 2
flash_point_f
-4.0 °F - closed cup
flash_point_c
-20 °C - closed cup
Seznamy omezení vyplývajících z předpisů
Seznamy omezení vyplývajících z předpisů jsou poskytovány zejména pro chemické produkty. Pro jiné než chemické produkty lze poskytovat pouze omezené informace. Žádný záznam znamená, že v seznamech není obsažena žádná ze součástí. Povinností uživatele je zajistit bezpečné a zákonné použití produktu.
EU REACH Annex XVII (Restriction List)
Osvědčení o analýze (COA)
Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Zákazníci si také prohlíželi
Sortimentní položky
Learn about the UV-spectrometric determination of the K270 nm value of olive oil, assessing the UV absorbance at 270 nm to ensure quality and compliance with regulatory standards.
Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..
Obraťte se na technický servis.