Přejít k obsahu
Merck
Všechny fotografie(3)

Key Documents

346187

Sigma-Aldrich

Trioctylphosphine oxide

technical grade, 90%

Synonyma:

(Oct)3PO, TOPO®

Přihlásitk zobrazení cen stanovených pro organizaci a smluvních cen


About This Item

Lineární vzorec:
[CH3(CH2)7]3PO
Číslo CAS:
Molekulová hmotnost:
386.63
Beilstein/REAXYS Number:
1796648
EC Number:
MDL number:
UNSPSC Code:
12352119
PubChem Substance ID:
NACRES:
NA.22

grade

technical grade

assay

90%

form

solid

bp

201-202 °C/2 mmHg (lit.)

mp

50-52 °C (lit.)

functional group

phosphine oxide

SMILES string

CCCCCCCCP(=O)(CCCCCCCC)CCCCCCCC

InChI

1S/C24H51OP/c1-4-7-10-13-16-19-22-26(25,23-20-17-14-11-8-5-2)24-21-18-15-12-9-6-3/h4-24H2,1-3H3

InChI key

ZMBHCYHQLYEYDV-UHFFFAOYSA-N

Hledáte podobné produkty? Navštivte Průvodce porovnáváním produktů

Application

Used as an extraction or stabilizing agent; also useful as a capping ligand for the production of quantum dots such as CdSe.

Legal Information

TOPO is a registered trademark of Life Technologies

pictograms

Corrosion

signalword

Danger

Hazard Classifications

Aquatic Chronic 3 - Eye Dam. 1 - Skin Irrit. 2

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

446.0 °F - closed cup

flash_point_c

230 °C - closed cup

ppe

dust mask type N95 (US), Eyeshields, Gloves


Osvědčení o analýze (COA)

Vyhledejte osvědčení Osvědčení o analýze (COA) zadáním čísla šarže/dávky těchto produktů. Čísla šarže a dávky lze nalézt na štítku produktu za slovy „Lot“ nebo „Batch“.

Již tento produkt vlastníte?

Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.

Navštívit knihovnu dokumentů

Zákazníci si také prohlíželi

Huwei Feng et al.
Frontiers in chemistry, 8, 266-266 (2020-05-07)
Quantum dot light-emitting diodes (QLEDs) have been considered as the most promising candidate of light sources for the new generation display and solid-state lighting applications. Especially, the performance of visible QLEDs based on II-VI quantum dots (QDs) has satisfied the
Sanjeev Kumar Mahto et al.
Toxicology in vitro : an international journal published in association with BIBRA, 24(4), 1070-1077 (2010-04-07)
With the widespread use of quantum dots (QDs), the likelihood of exposure to QDs has been assumed to have increased substantially. Recently, QDs have been employed in numerous biological and medical applications. However, there is a lack of toxicological data
Raju Banda et al.
Journal of hazardous materials, 213-214, 1-6 (2012-02-18)
The separation and recovery of Mo and Co from the synthetic chloride leach liquors of petroleum refining catalyst has been investigated by employing TOPO and Alamine 308 as extractants. The synthetic leach liquor contained Mo 394 mg/L, Al 1782 mg/L
Shuang-Yuan Zhang et al.
Advanced materials (Deerfield Beach, Fla.), 24(32), 4369-4375 (2012-07-19)
The preparation of vertically or horizontally aligned self-assemblies of CoP nanowires is demonstrated for the first time by aging them in the reaction solution for a sufficient time at 20 or 0 °C. This strategy opens up a way for
Wesley E Smith et al.
ACS nano, 6(11), 9475-9484 (2012-10-09)
Semiconductor quantum dots (Qdots) are a promising new technology with benefits in the areas of medical diagnostics and therapeutics. Qdots generally consist of a semiconductor core, capping shell, and surface coating. The semiconductor core of Qdots is often composed of

Náš tým vědeckých pracovníků má zkušenosti ve všech oblastech výzkumu, včetně přírodních věd, materiálových věd, chemické syntézy, chromatografie, analytiky a mnoha dalších..

Obraťte se na technický servis.