Skip to Content
Merck
  • Decreased serum levels of D-serine in patients with schizophrenia: evidence in support of the N-methyl-D-aspartate receptor hypofunction hypothesis of schizophrenia.

Decreased serum levels of D-serine in patients with schizophrenia: evidence in support of the N-methyl-D-aspartate receptor hypofunction hypothesis of schizophrenia.

Archives of general psychiatry (2003-06-11)
Kenji Hashimoto, Takeshi Fukushima, Eiji Shimizu, Naoya Komatsu, Hiroyuki Watanabe, Naoyuki Shinoda, Michiko Nakazato, Chikara Kumakiri, Shin-ichi Okada, Hisanori Hasegawa, Kazuhiro Imai, Masaomi Iyo
ABSTRACT

The hypofunction of the N-methyl-D-aspartate (NMDA) subtype of glutamate receptors has been implicated in the pathophysiology of schizophrenia. Several lines of evidence suggest that D-serine may function as an endogenous agonist of the glycine site of the NMDA receptor. The aim of this study was to examine whether serum levels of D- and L-serine in patients with schizophrenia are different from those of healthy controls. Forty-two patients with schizophrenia and 42 age- and sex-matched healthy controls were enrolled in this study. Symptoms were assessed using the Brief Psychiatric Rating Scale. Serum levels of total serine and D- and L-serine were measured by high-performance liquid chromatography. Serum levels of D-serine in the patients with schizophrenia were significantly (z = -3.30, P =.001) lower than those of healthy controls. In contrast, serum levels of total (D and L) serine (z = -2.40, P =.02) and L-serine (z = -2.49, P =.01) in the schizophrenic patients were significantly higher than those of controls. In addition, the percentage of D-serine in the total serine in the schizophrenic patients was significantly (z = -4.78, P<.001) lower than that of controls, suggesting that the activity of serine racemase, an enzyme catalyzing the formation of D-serine from L-serine, may have been reduced in the schizophrenic patients. Reduced levels of D-serine may play a role in the pathophysiology of schizophrenia, and serum D- and L-serine levels might provide a measurable biological marker for schizophrenia.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Glycine, 99%, FCC
Sigma-Aldrich
L-Tyrosine, FG
Sigma-Aldrich
L-Alanine, ≥99%
Sigma-Aldrich
Glycine, BioUltra, for molecular biology, ≥99.0% (NT)
Sigma-Aldrich
L-Tyrosine, BioUltra, ≥99.0% (NT)
Sigma-Aldrich
Glycine, puriss. p.a., reag. Ph. Eur., buffer substance, 99.7-101% (calc. to the dried substance)
Sigma-Aldrich
L-Alanine, BioUltra, ≥99.5% (NT)
Sigma-Aldrich
Glycine, tested according to Ph. Eur.
Sigma-Aldrich
4-Hydroxyphenylacetic acid, 98%
Sigma-Aldrich
Glycine, ACS reagent, ≥98.5%
Sigma-Aldrich
Glycine, meets analytical specification of Ph. Eur., BP, USP, 99-101% (based on anhydrous substance)
Sigma-Aldrich
N-Acetyl-L-aspartic acid, ≥99.0% (T)
Sigma-Aldrich
L-Alanine, from non-animal source, meets EP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
L-Alanine, ≥98% (TLC)
Sigma-Aldrich
L-Tyrosine, from non-animal source, meets EP, USP testing specifications, suitable for cell culture, 99.0-101.0%
Sigma-Aldrich
L-Tyrosine, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
Homovanillic acid, Fluorimetric reagent
Sigma-Aldrich
L-Threonine, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 99.0-101.0%
Sigma-Aldrich
L-Aspartic acid, from non-animal source, meets EP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
Glycine, suitable for electrophoresis, ≥99%
Sigma-Aldrich
Glycine, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
Glycine, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, ≥98.5%
Sigma-Aldrich
L-Glutamine solution, 200 mM, solution, sterile-filtered, BioXtra, suitable for cell culture
Sigma-Aldrich
L-Glutamine solution, 200 mM, Hybri-Max, sterile-filtered, suitable for hybridoma
SAFC
L-Aspartic acid
SAFC
Glycine
SAFC
L-Tyrosine
Sigma-Aldrich
L-Threonine, reagent grade, ≥98% (HPLC)
Sigma-Aldrich
L-Aspartic acid, BioXtra, ≥99% (HPLC)
Sigma-Aldrich
Glycine, BioXtra, ≥99% (titration)