Accéder au contenu
Merck
  • Quantification of piperacillin, tazobactam, cefepime, meropenem, ciprofloxacin and linezolid in serum using an isotope dilution UHPLC-MS/MS method with semi-automated sample preparation.

Quantification of piperacillin, tazobactam, cefepime, meropenem, ciprofloxacin and linezolid in serum using an isotope dilution UHPLC-MS/MS method with semi-automated sample preparation.

Clinical chemistry and laboratory medicine (2014-10-11)
Johannes Zander, Barbara Maier, Anna Suhr, Michael Zoller, Lorenz Frey, Daniel Teupser, Michael Vogeser
RÉSUMÉ

Recent studies have demonstrated highly variable blood concentrations of piperacillin, tazobactam, cefepime, meropenem, ciprofloxacin and linezolid in critically ill patients with a high incidence of sub-therapeutic levels. Consequently, therapeutic drug monitoring (TDM) of these antibiotics has to be considered, requiring robust and reliable routine analytical methods. The aim of the present work was to develop and validate a multi-analyte ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method for the simultaneous quantification of the above mentioned antibiotics. Sample preparation included a manual protein precipitation step followed by two-dimensional ultra high performance liquid chromatography (2D-UHPLC). Corresponding stable isotope-labeled substances were used as internal standards for all of the analytes, with the exception of tazobactam. The injected sample volume was 7 μL. The run time was 5.0 min. Inaccuracy was ≤8% and imprecision coefficient of variation (CV) was <9% for all analytes. Only minor matrix effects and negligible carry-over was observed. The method was found to be robust during the validation period. We were able to develop a reliable 2D-UHPLC-MS/MS method addressing analytes with highly heterogeneous physico-chemical properties. The novel assay may be an efficient tool for an optimized process workflow in clinical laboratories for important antibiotics in regards to TDM.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acide formique, reagent grade, ≥95%
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acide formique, ACS reagent, ≥96%
Sigma-Aldrich
Acide formique, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Méthanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Acide formique, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Acide formique, ACS reagent, ≥88%
Sigma-Aldrich
Méthanol, anhydrous, 99.8%
Sigma-Aldrich
Méthanol, Absolute - Acetone free
Sigma-Aldrich
Méthanol, BioReagent, ≥99.93%
Sigma-Aldrich
Méthanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
USP
Méthanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Méropénème trihydraté, ≥98% (HPLC)
Supelco
Méthanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acide formique, ≥95%, FCC, FG
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Piperacillin sodium salt, penicillin analog
Supelco
Méthanol, analytical standard
Sigma-Aldrich
Méthanol, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)
Sigma-Aldrich
Tazobactam sodium salt, β-lactamase inhibitor
Sigma-Aldrich
Acide formique solution, BioUltra, 1.0 M in H2O
Sigma-Aldrich
Méthanol, NMR reference standard
USP
Piperacillin, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.