76088

Supelco

Lufenuron

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Synonyme(s) :

1-[2,5-Dichloro-4-(1,1,2,3,3,3-hexafluoropropoxy)phenyl]-3-(2,6-difluorobenzoyl)urea

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
C17H8Cl2F8N2O3
Numéro CAS:
Poids moléculaire :
511.15
Numéro Beilstein :
8398291
Numéro MDL:
Code UNSPSC :
41116107
Nomenclature NACRES :
NA.24

Qualité

certified reference material
TraceCERT®

Niveau de qualité

Gamme de produits

TraceCERT®

Durée de conservation

limited shelf life, expiry date on the label

Fabricant/nom de marque

Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Format

neat

Température de stockage

2-8°C

Chaîne SMILES 

FC(C(F)(F)F)C(F)(F)Oc1cc(Cl)c(NC(=O)NC(=O)c2c(F)cccc2F)cc1Cl

InChI

1S/C17H8Cl2F8N2O3/c18-6-5-11(32-17(26,27)14(22)16(23,24)25)7(19)4-10(6)28-15(31)29-13(30)12-8(20)2-1-3-9(12)21/h1-5,14H,(H2,28,29,30,31)

Clé InChI

PWPJGUXAGUPAHP-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

This reference material (RM) is produced and certified in accordance with ISO/IEC 17025. This RM is traceable to primary material from an NMI, e.g. NIST or NMIJ. Certified content incl. uncertainty and expiry date are given on the certificate. Download your certificate at: http://www.sigma-aldrich.com

Lufenuron is an insect growth regulator used to control biting and sucking insects and belongs to the group of benzoylphenylurea insecticides. This systemic insecticide is known to be an inhibitor of chitin synthesis in the cuticle of insects. Lufenuron is used for the control of lepidopteran and coleopteran larvae and is extensively applied in cotton, maize, sugar beet, potatoes, grapes, citrus, and ornamentals farms. Lufenuron is also used in veterinary medicine as a flea control treatment and as an anti-fungal agent for dogs and cats.

Lufenuron is not approved for use in European Union (EU) as per Regulation (EC) No 1107/2009 (repealing Directive 91/414/EEC). However, the maximum residue level (MRL) for Lufenuron (any ratio of constituent isomers) is set from 0.01 mg/kg to 2 mg/kg for products of plant and animal origin following Reg. (EU) 2020/856. The Korea Food and Drug Administration (KFDA) has established an MRL of 0.01 to 0.2 ppm.

Lufenuron has to be monitored in the Multiannual Control Programme for Pesticides Residues (MACP), run within the EU and EFTA in/on products of plant origin.

Application

The certified reference material (CRM) is intended to be used as a calibrant for chromatography and other analytical techniques. Lufenuron CRM can also be used to: 
  • Evaluate the dissipation of lufenuron residues as a function of time and calculate the pre-harvest intervals on treated Chinese cabbages grown under greenhouse conditions
  • Determine the effect of lufenuron exposure on different health biomarkers of common carp (Cyprinus carpio)
  • Examine the effects of chitin-synthesis interruption during the development and reproduction of Drosophila melanogaster when administered with lufenuron
  • Study the effects of lufenuron on the development and mortality of Lobesia botrana eggs and larvae and also on adult fecundity, fertility, and longevity
  • Investigate the presence of chitin in ovaries of Rhodnius prolixus and study the effect of lufenuron on oogenesis and egg-laying

Produits recommandés

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Informations légales

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogrammes

Exclamation markEnvironment

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Aquatic Acute 1 - Aquatic Chronic 1 - Skin Sens. 1

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

>338.0 °F - (External MSDS)

Point d'éclair (°C)

> 170 °C - (External MSDS)


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique