Accéder au contenu
Merck
Toutes les photos(1)

Principaux documents

57030-U

Supelco

Rampe à vide pour SPE Visiprep, exempte de PTFE

standard, 12-port model

Synonyme(s) :

Rampe à vide pour SPE à 12 voies, pour tuyaux de cartouche

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41121800
Nomenclature NACRES :
NB.21
Le tarif et la disponibilité ne sont pas disponibles actuellement.

Matériaux

UHMW PE frit
polypropylene tube

Niveau de qualité

Agence

suitable for DIN 38407-42
suitable for EPA 1633
suitable for EPA 533
suitable for EPA 537.1
suitable for EPA ACB B21-02
suitable for EPA ACB B23-05b
suitable for EPA OTM-45
suitable for GB 31604.35-2016
suitable for ISO 21675 2019
suitable for ISO 25101
suitable for ISO/CEN 15968-2010

Conformité réglementaire

suitable for FDA C-010.02

Gamme de produits

Visiprep

Technique(s)

solid phase extraction (SPE): suitable

Adéquation

suitable for (for PFAS testing)

Application(s)

environmental
food and beverages

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Les rampes à vide et accessoires pour l'extraction en phase solide Visiprep permettent d'automatiser la préparation et la purification des échantillons liquides de laboratoire par extraction en phase solide. Utilisée avec une pompe à vide, la rampe Visiprep™ peut extraire simultanément jusqu'à 12 ou 24 échantillons, ce qui permet de considérablement accroître la cadence d'analyse tout en réduisant le temps de manipulation nécessaire à la préparation des échantillons par rapport aux méthodes par extraction liquide-liquide. Les rampes à vide Visiprep sont équipées d'une soupape casse-vide et d'un couvercle indépendant pour un contrôle précis du débit et une utilisation simple et en toute sécurité.Grâce à nos soupapes de régulation de débit, vous pouvez adapter précisément le débit dans chaque tube en tournant les soupapes à vis individuelles intégrées au couvercle. Nos rampes standard récemment optimisées peuvent être utilisées avec les méthodes d'analyse de PFAS basées sur la SPE. Tous les composants critiques qui contiennent des PFAS (comme le PTFE) ont été remplacés par des alternatives sans PFAS comme le polyéthylène de poids moléculaire ultra-élevé (PE UHMW) ou l'acier inoxydable (guides d'aiguille). L'exposition de la cuve en verre aux solvants puissants ne provoque ni dissolution, ni embuage, ni décoloration. Le support de rampe peut accueillir un passeur automatique d'échantillons ou de petits flacons à scintillation, des tubes à essai de 10 mm ou 16 mm, ou des fioles jaugées de 1, 2, 5 ou 10 ml. Une plaque disponible en option peut loger jusqu'à dix flacons à scintillation de 20 ml sur le modèle à 12 orifices. La soupape casse-vide améliore la régulation du niveau de vide et sécurise la fermeture de la soupape. Cette soupape à vis est munie d'un joint d'étanchéité conique (désormais sans PTFE) en polyéthylène de poids moléculaire ultra-élevé.Serrer la vis garantit une herméticité totale sans aucune fuite au niveau de la soupape.Desserrer la vis rompt la fermeture hermétique et permet de casser immédiatement le vide afin de stopper les extractions ou de soulever le couvercle de la rampe. Quatre pieds d'une longueur de 5 cm vous permettent de poser le couvercle sur un plan de travail en maintenant les tubes de SPE à la verticale. Cela permet d'éviter tout contact entre les guides de solvant et la surface de travail et d'empêcher les détériorations et les contaminations. L'accessoire de séchage, vendu séparément, s'installe sur la rampe en quelques minutes et est compatible avec tous les gaz inertes. L'accessoire de séchage est aussi utile pour concentrer les échantillons récupérés. Le débit de gaz peut être réglé de manière indépendante dans chaque tube.

Application

La rampe à vide pour SPE Visiprep a servi à effectuer une extraction en phase solide pour séparer les polyphénols présents dans les raisins, afin de déterminer leur teneur en polyphénols par LC-MS.[1] Elle a été utilisée pour concentrer et purifier des échantillons obtenus par extraction avec des solvants à partir d′eaux de surface et de sédiments d′eaux usées.[2] Elle a également permis d′extraire et de doser l′œstrone présente dans l′eau par SPE-ELISA.[3]

Caractéristiques et avantages

  • Soupapes à vis brevetées dans chacun des orifices de SPE, pour un contrôle précis du débit.
  • Pas de dissolution, embuage ou décoloration de la cuve en verre lorsqu'elle est exposée aux solvants.
  • Des pieds sur le couvercle permettent à l'utilisateur de poser facilement celui-ci sur une surface de travail après l'avoir retiré de la rampe.
  • Le casse-vide à vis résistant aux solvants et la soupape assurent une meilleure étanchéité et un meilleur contrôle du vide. La soupape se raccorde aux tubes à vide de 1/4″.
  • Le support pour récipients de collecte en PP peut accueillir des flacons de passeur automatique d'échantillons ; de petits flacons à scintillation (22,75 mm de d.e. recommandé) ; des tubes à essai de 10 et 16 mm ; et des fioles jaugées de 1, 2, 5 et 10 ml. Une plaque pour flacons à scintillation de 20 ml est disponible en option pour les modèles à 12 orifices.

Informations légales

Visiprep is a trademark of Sigma-Aldrich Co. LLC

Produit(s) apparenté(s)

Réf. du produit
Description
Tarif

Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

Si vous avez besoin d'assistance, veuillez contacter Service Clients

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Kristina Mladenov et al.
Journal of cosmetic science, 71(5), 251-262 (2020-10-07)
Caffeine is extensively used in cellulite and hair growth cosmetic products. Regulations in the field of cosmetics require manufacturers to list caffeine in the ingredient list on product labels, but its exact content in these products is not declared. On
Aysha Ferdoushi et al.
Frontiers in oncology, 10, 1601-1601 (2020-09-29)
Schwann cells (SCs), the glial component of peripheral nerves, have been identified as promoters of pancreatic cancer (PC) progression, but the molecular mechanisms are unclear. In the present study, we aimed to identify proteins released by SCs that could stimulate
Nazli Bahrami et al.
The Journal of steroid biochemistry and molecular biology, 200, 105641-105641 (2020-03-11)
The aromatase inhibitors (AIs), letrozole (Femar®/Femara®) and exemestane (Aromasin®), are widely used to treat estrogen receptor (ER) positive breast cancer in postmenopausal patients. In the setting of metastatic breast cancer, these drugs may be used after another causing new responses
Development of a solid-phase extraction-enzyme-linked immunosorbent assay method for the determination of estrone in water.
Li, Zhilan, et al.
Analytica Chimica Acta, 503, 171-177 (2004)
Guangdi Wang et al.
Journal of environmental monitoring : JEM, 14(5), 1353-1364 (2012-03-23)
Endocrine disrupting compounds (EDCs), represented by steroid hormones, organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), and bisphenol A have been determined in four sediment cores from the Gulf of Mexico, from New Orleans surface water (Lake Pontchartrain and Mississippi River), and

Articles

A complete reversed phase HPLC-ELSD workflow, including sample preparation for the analysis of Polysorbate 80 in a monoclonal antibody formulation.

Simultaneous determination of 27 PFAS chemical compounds after enriching the water samples with SPE using a Supelclean® ENVI-WAX weak anion exchange tube.

Simultaneous determination of 27 PFAS chemical compounds after enriching the water samples with SPE using a Supelclean® ENVI-WAX weak anion exchange tube.

Simultaneous determination of 27 PFAS chemical compounds after enriching the water samples with SPE using a Supelclean® ENVI-WAX weak anion exchange tube.

Afficher tout

Questions

1–9 of 9 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. What is the spacing between ports for the 12 and 24 manifolds. Will spacing accommodate 60mL reservoirs such as PN 57022 in neighboring positions.

    1 answer
    1. Following are the dimensions for the valve placements.
      Visiprep 12 Port, Product numbers 57030-U & 57044
      1 1/8" (1.14") Between valves (center to center)
      1 5/8" Between rows (center to center)

      Visiprep 24 Port, Product numbers 57250-U & 57265
      7/8" (0.875") Between valves (center to center)
      1 3/8" Between rows (center to center)

      All ports on the 12 and 24 vacuum manifolds can only be used simultaneously with 1, 3, and 6mL tubes. In order to use all ports of the manifold with 12, 20, or 60 mL SPE tubes, Long Stem Flow Control Valves are required – see product 57048.

      Helpful?

  4. What leads to the vacuum gauge needle on the Visiprep SPE Manifold to bounce back and forth instead of being steady?

    1 answer
    1. The fluctuation of the vacuum gauge needle usually indicates a faulty diaphragm, necessitating the replacement of the entire gauge. Part number 57035-U is the Vacuum Gauge with Bleed Valve for both the 12-Port and 24-Port Visiprep SPE Manifolds.
      For the Visiprep Vacuum Gauge, the gasket is an essential matched part and, as such, cannot be replaced independently of the other components.

      Helpful?

  5. What additional items are required to utilize Visiprep Manifold 57030-U?

    1 answer
    1. To operate both the standard Visiprep SPE Manifolds (57030-U and 57044) and the Visiprep DL Manifolds (57265 and 57250-U), you will need a vacuum pump and a Waste Trap Kit (57120-U). The waste trap should be installed between the manifold and pump to ensure that the waste going into the glass basin is pulled through the front gage and out into the waste trap.
      Other necessary items include:
      • SPE tube of choice
      • Vials, test tubes, or other collection vessels that fit the polypropylene collection vessel racks, accommodating autosampler vials, small scintillation vials, 10 and 16 mm test tubes, and 1, 2, 5, and 10-mL volumetric flasks. An optional plate for 20 mL scintillation vials is available for 24-port models.

      Helpful?

  6. What is the maximum vacuum that the Visiprep Vacuum Manifold, Product 57030-U, can handle?

    1 answer
    1. The maximum vacuum that the Visiprep Vacuum Manifold can handle is 20 inches of Mercury (Hg).

      Helpful?

  7. When I purchase the Visiprep SPE Vacuum Manifold, Product 57030-U, what additional components are required to begin using it immediately?

    1 answer
    1. The Visiprep SPE Vacuum Manifold (57030-U) includes most items which would be required for immediate operation. Additional required items are the SPE tubes themselves, a vacuum source, and tubing to connect the manifold to the vacuum source.

      Helpful?

  8. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  9. Do you have a recommendation for the tubing required to connect Visiprep™ SPE Vacuum Manifold (57030-U) to my vacuum source?

    1 answer
    1. Although any 1/4 inch ID flexible tubing should be suitable for this purpose, the product number Z255998-1PAK (10ft length) would be appropriate for this application.

      Helpful?

Reviews

No rating value

Active Filters

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique