Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
499609
Calcium chloride
anhydrous, powder, 99.99% trace metals basis
Synonyme(s) :
Calcium dichloride
About This Item
Produits recommandés
Qualité
anhydrous
Niveau de qualité
Pression de vapeur
0.01 mmHg ( 20 °C)
Essai
99.99% trace metals basis
Forme
powder
Technique(s)
cell culture | mammalian: suitable
Impuretés
≤150.0 ppm Trace Metal Analysis
pb
1935 °C/1 atm (lit.)
Pf
772 °C (lit.)
Solubilité
ethanol: very soluble(lit.)
Chaîne SMILES
[Cl-].[Cl-].[Ca++]
InChI
1S/Ca.2ClH/h;2*1H/q+2;;/p-2
Clé InChI
UXVMQQNJUSDDNG-UHFFFAOYSA-L
Vous recherchez des produits similaires ? Visite Guide de comparaison des produits
Description générale
- Higher thermal conductivity
- Chemical and thermal stability
- Non-toxic and less corrosive
Application
- As electrolyte in the reduction of solid zirconium dioxide by electro-deoxidation.
- A raw material to prepare composite adsorbent(activated carbon/silica gel/CaCl2) for cooling and dehumidification system.
- As a catalyst to synthesize tetrahydropyranyl ethers via tetrahydropyranylation of alcohols and phenols.
À utiliser avec
Mention d'avertissement
Warning
Mentions de danger
Conseils de prudence
Classification des risques
Eye Irrit. 2
Code de la classe de stockage
13 - Non Combustible Solids
Classe de danger pour l'eau (WGK)
WGK 1
Point d'éclair (°F)
Not applicable
Point d'éclair (°C)
Not applicable
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
Vous ne trouvez pas la bonne version ?
Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Les clients ont également consulté
Articles
Three approaches generate white light, including LED-based down-conversion for broader applications.
Three approaches generate white light, including LED-based down-conversion for broader applications.
Three approaches generate white light, including LED-based down-conversion for broader applications.
Three approaches generate white light, including LED-based down-conversion for broader applications.
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Helpful?
-
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdfHelpful?
-
-
Does anyone know how to open the glass ampoule that it comes in? It's just one long tube with no neck.
1 answer-
In order to open the glass ampoule, it is recommended to use an ampoule opener such as Product Z693847 (Scienceware® Break-Safe ™ ampule opener). Here is a short video on how to use the product:
https://www.sigmaaldrich.com/video/labware/bel-art-ampule-opener.htmlAn alternative solution is to groove the bulb using a glass cutting tool such as the following:
- Ref. Z169064: diamond glass cutter
- Ref. Z150770: glass tube cutterAfter marking the circumference of the bulb evenly, grab puncture resistant gloves or nitrile gloves and a thick cloth to wrap around the bulb. The bulk can then be broken by exerting pressure on the marking with the end-user's thumb.
Note that the ampoules are intended for single use. After the bulb is broken, it is suggested to use the product at one time. It is not recommended to store unused surplus. To keep the unused product after opening, it is recommended to transfer the unused material to another clean, properly sealed container for storage.
Helpful?
-
Active Filters
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique