Accéder au contenu
Merck

Antibodies to post-translationally modified insulin in type 1 diabetes.

Diabetologia (2015-09-10)
Rocky Strollo, Chiara Vinci, Mayda H Arshad, David Perrett, Claudio Tiberti, Francesco Chiarelli, Nicola Napoli, Paolo Pozzilli, Ahuva Nissim
RÉSUMÉ

Insulin is the most specific beta cell antigen and a potential primary autoantigen in type 1 diabetes. Insulin autoantibodies (IAAs) are the earliest marker of beta cell autoimmunity; however, only slightly more than 50% of children and even fewer adults newly diagnosed with type 1 diabetes are IAA positive. The aim of this investigation was to determine if oxidative post-translational modification (oxPTM) of insulin by reactive oxidants associated with islet inflammation generates neoepitopes that stimulate an immune response in individuals with type 1 diabetes. oxPTM of insulin was generated using ribose and various reactive oxygen species. Modifications were analysed by SDS-PAGE, three-dimensional fluorescence and MS. Autoreactivity to oxPTM insulin (oxPTM-INS) was observed by ELISA and western blotting, using sera from participants with type 1 or type 2 diabetes and healthy controls as probes. IAA was measured using the gold-standard radiobinding assay (RBA). MS of oxPTM-INS identified chlorination of Tyr16 and Tyr26; oxidation of His5, Cys7 and Phe24; and glycation of Lys29 and Phe1 in chain B. Significantly higher binding to oxPTM-INS vs native insulin was observed in participants with type 1 diabetes, with 84% sensitivity compared with 61% sensitivity for RBA. oxPTM-INS autoantibodies and IAA co-existed in 50% of those with type 1 diabetes. Importantly 34% of those with diabetes who were IAA negative were oxPTM-INS positive. Altogether, 95% of participants with type 1 diabetes presented with autoimmunity to insulin by RBA, oxPTM-INS or both. Binding to oxPTM-INS was directed towards oxPTM-INS fragments with slower mobility than native insulin. These data suggest that oxPTM-INS is a potential autoantigen in individuals with new-onset type 1 diabetes.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Peroxyde d'hydrogène solution, contains inhibitor, 30 wt. % in H2O, ACS reagent
Sigma-Aldrich
Peroxyde d'hydrogène solution, 30 % (w/w) in H2O, contains stabilizer
Sigma-Aldrich
DL-Dithiothréitol solution, BioUltra, for molecular biology, ~1 M in H2O
Sigma-Aldrich
Peroxyde d'hydrogène solution, 50 wt. % in H2O, stabilized
Supelco
DL-Dithiothréitol solution, 1 M in H2O
Sigma-Aldrich
Peroxyde d'hydrogène solution, contains ~200 ppm acetanilide as stabilizer, 3 wt. % in H2O
Sigma-Aldrich
Peroxyde d'hydrogène solution, contains inhibitor, 35 wt. % in H2O
Sigma-Aldrich
Peroxyde d'hydrogène solution, purum p.a., ≥35% (RT)
Sigma-Aldrich
Peroxyde d'hydrogène solution, contains inhibitor, 30 wt. % in H2O, meets USP testing specifications
Sigma-Aldrich
Peroxyde d'hydrogène solution, 34.5-36.5%
Sigma-Aldrich
L-(+)-Ribose, ≥98% (GC)
Sigma-Aldrich
Eosin B Solution, 0.1% aqueous solution