Accéder au contenu
Merck
  • Stability-indicating RP-LC method for determination of azilsartan medoxomil and chlorthalidone in pharmaceutical dosage forms: application to degradation kinetics.

Stability-indicating RP-LC method for determination of azilsartan medoxomil and chlorthalidone in pharmaceutical dosage forms: application to degradation kinetics.

Analytical and bioanalytical chemistry (2014-09-06)
Walid M Ebeid, Ehab F Elkady, Asmaa A El-Zaher, Ramzia I El-Bagary, Gabor Patonay
RÉSUMÉ

A RP-LC method was developed and validated for simultaneous determination of the active components, azilsartan medoxomil (AZL) and chlorthalidone (CLT), in their novel antihypertensive combined recipe. The chromatographic separation was achieved on an Eclipse XDB-C18 (4.6 × 150 mm, 5 μm) column using a mobile phase consisting of methanol/potassium hydrogen phosphate buffer (pH 8, 0.05 M) (40:60, v/v) in isocratic mode. The flow rate was maintained at 0.8 mL min(-1) at ambient temperature. Detection was carried out at 210 nm. The method was validated according to the ICH guidelines. Linearity, accuracy, and precision were satisfactory over the concentration range of 5.0-50.0 and 2.5-25.0 μg mL(-1) for AZL and CLT, respectively (r (2) = 0.9999). LODs for AZL and CLT were 0.90 and 0.32 μg mL(-1), whereas LOQs were 2.72 and 0.98 μg mL(-1), respectively. Both drugs were subjected to forced degradation studies under hydrolysis (neutral, acidic, and alkaline), oxidative, and photolytic extensive stress conditions. The proposed method is stability indicating by the resolution of the investigated drugs from their degradation products. Moreover, the kinetics of the acidic degradation of AZL as well as the kinetics of the alkaline degradation of CLT were investigated. Arrhenius plots were constructed and the apparent first-order rate constants, half-life times, shelf-life times, and the activation energies of the degradation processes were calculated. The method was successfully applied for the determination of the studied drugs simultaneously in their coformulated tablet. The developed method is specific and stability indicating for the quality control and routine analysis of the cited medications in their pharmaceutical preparations.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Peroxyde d'hydrogène solution, contains inhibitor, 30 wt. % in H2O, ACS reagent
Sigma-Aldrich
Peroxyde d'hydrogène solution, 30 % (w/w) in H2O, contains stabilizer
Sigma-Aldrich
Acétate d′ammonium, ACS reagent, ≥97%
Sigma-Aldrich
Acétate d′ammonium, ≥99.99% trace metals basis
Sigma-Aldrich
Peroxyde d'hydrogène solution, 50 wt. % in H2O, stabilized
Sigma-Aldrich
Peroxyde d'hydrogène solution, 30% (w/w), puriss. p.a., reag. ISO, reag. Ph. Eur.
Sigma-Aldrich
Acétate d′ammonium, for molecular biology, ≥98%
Sigma-Aldrich
Acétate d′ammonium solution, for molecular biology, 7.5 M
Sigma-Aldrich
Peroxyde d'hydrogène solution, contains ~200 ppm acetanilide as stabilizer, 3 wt. % in H2O
Sigma-Aldrich
Peroxyde d'hydrogène solution, contains inhibitor, 35 wt. % in H2O
Sigma-Aldrich
Peroxyde d'hydrogène solution, purum p.a., ≥35% (RT)
Supelco
Acétate d′ammonium, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Acétate d′ammonium, 99.999% trace metals basis
Millipore
Peroxyde d'hydrogène solution, 3%, suitable for microbiology
Sigma-Aldrich
Acétate d′ammonium, reagent grade, ≥98%
Supelco
Peroxyde d'hydrogène solution, ≥30%, for trace analysis
Sigma-Aldrich
Peroxyde d'hydrogène solution, contains inhibitor, 30 wt. % in H2O, meets USP testing specifications
Sigma-Aldrich
Peroxyde d'hydrogène solution, 34.5-36.5%
Supelco
Peroxyde d'hydrogène solution, 30 % (w/w), for ultratrace analysis
Sigma-Aldrich
Acétate d′ammonium solution, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Acétate d′ammonium, BioXtra, ≥98%
Sigma-Aldrich
Acétate d′ammonium, BioUltra, for molecular biology, ≥99.0%
Sigma-Aldrich
Peroxyde d'hydrogène solution, tested according to Ph. Eur.
Sigma-Aldrich
Ser-Phe-Leu-Leu-Arg-Asn-Pro-Asn-Asp-Lys-Tyr-Glu-Pro-Phe, ≥97% (HPLC)