Accéder au contenu
Merck
Toutes les photos(1)

Documents

GE28-9269-80

HiScreen Capto MMC

Cytiva 28-9269-80

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
23151817
Nomenclature NACRES :
NA.56

Description

Ion Exchanger Type (value)

Conditionnement

pkg of 1 ea

Fabricant/nom de marque

Cytiva 28-9269-80

Paramètres

44 psi

Taille du lit

7.7 mm × 100 mm

Volume du lit

4.7 mL

D.I. de la colonne

7.7 mm

Matrice

highly cross-linked agarose

Taille moy. des particules

75 μm (d50v)

cleaning

2-14

working range

2-12

Capacité

>45 mg binding capacity (BSA/ml medium at 30 mS/cm)

Adéquation

suitable for bioprocess medium

Description générale

HiScreen Capto MMC columns are prepacked with Capto MMC ion exchange chromatography medium, and are part of the process development platform available from Cytiva. The columns are an excellent choice for method optimization and parameter screening.

The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.

If necessary, two columns can easily be connected in series to give a bed height of 2NA cm.

Media prepacked in HiScreen Capto IEX columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.

Caractéristiques et avantages

  • Capto MMC is a multimodal cation exchanger with a different selectivity compared with traditional ion exchangers. It can be used to bind proteins at the conductivity of the feed material and to solve specific purification challenges.
  • Prepacked, ready-to-use columns for convenient process development optimization.
  • 1NA cm bed height of HiScreen columns is designed to allow method optimization and parameter screening.
  • Easily connected in series to achieve 2NA cm bed height.
  • Small bed volume gives fast results and minimal sample/buffer consumption.
  • Reproducible results, scalable to BioProcess columns packed with the same media using the same linear fluid velocity.

Stockage et stabilité

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol)

Remarque sur l'analyse

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Informations légales

Capto is a trademark of Cytiva
HiScreen is a trademark of Cytiva

Produit(s) apparenté(s)

Pictogrammes

Flame

Mention d'avertissement

Warning

Mentions de danger

Code de la classe de stockage

3 - Flammable liquids


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique