Accéder au contenu
Merck
Toutes les photos(1)

Documents

KWL6A10HH1

Millipore

Milligard® LPB 0.5 µm nominal, Opticap® XL Capsule

nominal pore size 0.5 μm, Opticap® XL 10, cartridge nominal length 10 in. (25 cm), filter diam. 5.7 in. (14.5 cm)

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
23151806

Matériaux

mixed cellulose esters (MCE) membrane
polyester support
polypropylene filter
polypropylene housing
silicone seal

Niveau de qualité

Conformité réglementaire

FDA 21CFR177-182 (all component materials)

Stérilité

non-sterile

Mode de stérilisation compatible

autoclavable compatible

Gamme de produits

Opticap® XL 10

Caractéristiques

hydrophilic

Fabricant/nom de marque

Opticap®

Paramètres

1 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure

Technique(s)

prefiltration: suitable

Longueur nominale des cartouches

10 in. (25 cm)

device L

33.5 cm (13.2 in.)

device size

10 in.

Diam. du filtre

5.7 in. (14.5 cm)

filter filtration area

0.8 m2

Diam. du raccord d'entrée

9/16 in.

inlet to outlet width

33.5 cm (13.2 in.)

Diam. du raccord de sortie

9/16 in.

Impuretés

≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.5 EU/mL bacterial endotoxins (LAL test, sample aqueous extraction)

Matrice

Milligard® LPB

Dimension de pores

0.5 μm nominal pore size
0.5 μm pore size

Raccords

(14 mm (9/16 in.) Hose Barb Inlet and Outlet)

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Device Configuration: Capsule

Caractéristiques et avantages

Single Layer

Conditionnement

Double Easy-Open bag

Caractéristiques

Filter Grade: Low Protein Binding Milligard® Media

Notes préparatoires

Sterilization Method:
3 autoclave cycles of Sterilization Method: 30min at 121°C; not in-line steam sterilizable

This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21CFR210.3(b)(6).

Remarque sur l'analyse

Gravimetric Extractables: ≤ 105 mg per capsule after a 5 L flush and 24 hours in water at controlled room temperature.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 5 L

Autres remarques

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of Opticap® XL Capsules and Opticap® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

Informations légales

MILLIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Not finding the right product?  

Try our Outil de sélection de produits.


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique