Skip to Content
Merck
  • Comparison of serum and urinary levels of modified nucleoside, 1-methyladenosine, in cancer patients using a monoclonal antibody-based inhibition ELISA.

Comparison of serum and urinary levels of modified nucleoside, 1-methyladenosine, in cancer patients using a monoclonal antibody-based inhibition ELISA.

The Tohoku journal of experimental medicine (1995-05-01)
S Ishiwata, K Itoh, T Yamaguchi, N Ishida, M Mizugaki
ABSTRACT

To evaluate the clinical usefulness of serum 1-methyladenosine, several modifications have been made in our previously established inhibition ELISA system. Horseradish peroxidase (HRP) labeled anti-mouse IgG and 3,3',5,5'-tetramethylbenzidine (TMBZ) were used as a secondary antibody and a substrate, respectively. The second blocking was done just before the addition of the secondary antibody. The standard curve of the modified ELISA system showed good linearity between 1 and 1,000 ng/ml, and the detection limit was 50 pg/well. Using the ultrafiltrated-serum samples, serum 1-methyladenosine levels in healthy individuals and cancer patients were determined. The mean level of 1-methyladenosine in 31 healthy individuals was 28.3 +/- 7.9 ng/ml, and cut off value was set at 44.1 ng/ml (Mean+ 2SD). In cancer patients, elevated levels of serum 1-methyladenosine above the cut off value were detected in 4 out of 25 cases tested, though 11 cases had elevated urinary 1-methyladenosine levels above the cut off value (3.23 nmol/mumol creatinine). Since 1-methyladenosine has no interaction with serum proteins and its molecular weight is quite low, it might be rapidly excreted into the urine.

MATERIALS
Product Number
Brand
Product Description

Supelco
L-Leucine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
L-Leucine, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
L-Tyrosine, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Glycine, analytical standard, for nitrogen determination according to Kjeldahl method
Supelco
L-Threonine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
L-Tyrosine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
L-Valine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
L-Alanine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Supelco
L-Alanine, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Glycine, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Glycine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
L-Alanine, ≥99%
Supelco
L-Valine, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Glycine, puriss. p.a., reag. Ph. Eur., buffer substance, 99.7-101% (calc. to the dried substance)
Sigma-Aldrich
Glycine, ACS reagent, ≥98.5%
SAFC
Glycine
SAFC
L-Tyrosine
Sigma-Aldrich
L-Threonine, BioXtra, ≥99.5% (NT)
Sigma-Aldrich
L-Valine, BioUltra, ≥99.5% (NT)
Sigma-Aldrich
L-Tyrosine, BioUltra, ≥99.0% (NT)
Sigma-Aldrich
Glycine, BioUltra, for molecular biology, ≥99.0% (NT)
Sigma-Aldrich
L-Lysine, crystallized, ≥98.0% (NT)
Sigma-Aldrich
L-Tyrosine, FG
Sigma-Aldrich
Glycine, 99%, FCC
Sigma-Aldrich
L-Leucine, 99%, FG
Sigma-Aldrich
L-Leucine, BioUltra, ≥99.5% (NT)
Sigma-Aldrich
Glycine, tested according to Ph. Eur.
SAFC
L-Threonine
SAFC
L-Valine
Sigma-Aldrich
Glycine, meets analytical specification of Ph. Eur., BP, USP, 99-101% (based on anhydrous substance)