Accéder au contenu
Merck

Selective extraction of antimycotic drugs from sludge samples using matrix solid-phase dispersion followed by on-line clean-up.

Analytical and bioanalytical chemistry (2014-09-28)
Jorge Casado, Gabriela Castro, Isaac Rodríguez, María Ramil, Rafael Cela
RÉSUMÉ

An effective and selective, modular sample preparation method for the extraction of eight antimycotic drugs, belonging to three different chemical classes, from digested sludge samples is proposed. To this end, matrix solid-phase dispersion (MSPD) was on-line connected with a cationic exchanger solid-phase extraction (SPE) cartridge. Analytes were extracted from the MSPD syringe, which contained the freeze-dried sludge sample dispersed with C18 plus a clean-up layer of primary and secondary amine (PSA) sorbent, with 10 mL of methanol. This extract flowed also through the SPE cartridge, where target compounds remained trapped while neutral interferences are released. After discarding the MSPD syringe, analytes were recovered with 10 mL of methanol (0.5% in NH3) before LC-MS/MS determination using a hybrid quadrupole time-of-flight (QTOF) mass spectrometer furnished with an electrospray ionization (ESI) source. In comparison with previously published sample preparation methodologies, the developed approach greatly simplifies sample handling and reduces attenuation of ESI ionization for sample extracts when compared to standard solutions. The obtained absolute recoveries ranged between 70 and 118%, and the limits of quantification (LOQs) of the method varied between 5 and 8 ng g(-1). Four antimycotic drugs were ubiquitous in urban sludge samples, with maximum average concentrations (above 400 ng g(-1)) corresponding to clotrimazole (CTZ). The screening capabilities of the LC-QTOF-MS system demonstrated that the developed modular extraction and purification methodology might be useful for the selective extraction of other basic drugs (e.g., sertraline, amitryptiline, and amiodarone) from sludge.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Méthanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Méthanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acétate d′ammonium, ACS reagent, ≥97%
Sigma-Aldrich
Ammoniac solution, 7 N in methanol
Sigma-Aldrich
Acétate d′ammonium, ≥99.99% trace metals basis
Sigma-Aldrich
Méthanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Méthanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Méthanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Méthanol, Absolute - Acetone free
Sigma-Aldrich
Méthanol, anhydrous, 99.8%
Sigma-Aldrich
Acétate d′ammonium, for molecular biology, ≥98%
Sigma-Aldrich
Méthanol, BioReagent, ≥99.93%
Sigma-Aldrich
Méthanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Acétate d′ammonium solution, for molecular biology, 7.5 M
Supelco
Acétate d′ammonium, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Ammoniac solution, 0.4 M in dioxane
Sigma-Aldrich
Ammoniac solution, 2.0 M in ethanol
Sigma-Aldrich
Méthanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Ammonia, anhydrous, ≥99.98%
USP
Méthanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Ammoniac solution, 4 M in methanol
Sigma-Aldrich
Activated Charcoal Norit®, Norit® PK 1-3, from peat, steam activated, granular
Sigma-Aldrich
Ammoniac solution, 0.4 M in THF
Sigma-Aldrich
Acétate d′ammonium, 99.999% trace metals basis
Sigma-Aldrich
Ammoniac solution, 2.0 M in methanol
Sigma-Aldrich
Activated Charcoal Norit®, Norit® GAC 1240W, from coal, for potable water processing, steam activated, granular
Sigma-Aldrich
Carbon nanofibers, graphitized, platelets(conical), >98% carbon basis, D × L 100 nm × 20-200 μm
Sigma-Aldrich
Activated Charcoal Norit®, Norit® SX ultra, from peat, corresponds U.S. Food chemicals codex (3rd Ed.), steam activated and acid washed, highly purified, powder