Accéder au contenu
Merck

Beer volatile analysis: optimization of HS/SPME coupled to GC/MS/FID.

Journal of food science (2011-05-04)
Gustavo Charry-Parra, Maritza Dejesus-Echevarria, Fernando J Perez
RÉSUMÉ

A powerful technique was developed for the identification and quantification of 9 volatile compounds of beer, using headspace solid phase micro-extraction (HS/SPME) and gas chromatograph coupled to a mass spectrometer and a flame ionization detector (GC/MS/FID). Optimized parameters included type of fiber, desorption time, and exposure time. Optimization was achieved with standard solutions of the target compounds. All samples were analyzed in triplicate. An exposure time of 45 min with PDMS fiber in the sample headspace was enough to reach equilibrium of the phases. A desorption time of 15 min in the gas chromatograph injector was enough for the fiber to desorb the target compounds. It was found that less polar compounds were more readily absorbed by the fiber (for example, isoamyl acetate) than more polar compounds (for example, acetaldehyde), under the extraction conditions, due to the nature of the fiber. Extraction conditions are important criteria to perform a good quantification of volatile compounds. Concentrations found in sampled beer, for the compounds of interest, ranged between 0.32 and 41.7 ppm. Results show that the reproducibility of the technique depends on the compounds. Esters have higher values (RSD mean value 5.05%) than higher alcohols (RSD mean value 2.5%) and aldehydes (RSD 3.7%). The simplicity of the validated methodology enables its use as a regular quality control procedure for beer flavor analysis. This study describes a technique successfully used to identify and quantify volatiles of interest in beer that can be used for quality control purposes under normal brewery production conditions. The technique uses a gas chromatograph coupled to a mass spectrometer with a flame ionization detector.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Sigma-Aldrich
Isoamyl acetate, natural, ≥97%, FCC, FG
Sigma-Aldrich
Isoamyl acetate, ≥95%, FCC, FG
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Sigma-Aldrich
Isopentyl acetate, mixture of isomers, reagent grade, 98%
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
Fibres SPME polyacrylate (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
Fibres SPME Polydimethylsiloxane (PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
Unité de fibres SPME, Polydiméthylsiloxane/divinylbenzène (PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
SPME StableFlex fiber assortment kit, for use with manual holder
Supelco
SPME fiber assembly, Carbowax-Polyethylene Glycol (PEG) Coating, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Sigma-Aldrich
Isopentyl acetate, anhydrous, ≥99%