Accéder au contenu
Merck
  • Electrochemical in situ fabrication of titanium dioxide-nanosheets on a titanium wire as a novel coating for selective solid-phase microextraction.

Electrochemical in situ fabrication of titanium dioxide-nanosheets on a titanium wire as a novel coating for selective solid-phase microextraction.

Journal of chromatography. A (2014-07-20)
Yi Li, Min Zhang, Yaoxia Yang, Xuemei Wang, Xinzhen Du
RÉSUMÉ

A novel TiO2-nanosheets coated fiber for solid-phase microextraction (SPME) was fabricated by anodization of Ti wire substrates in ethylene glycol with concentrated NH4F. The in situ fabricated TiO2-nanosheets were densely embedded into Ti substrates with about 1μm long, 300nm wide and 80nm thick. The as-fabricated TiO2-nanosheets coating was employed to extract polycyclic aromatic hydrocarbons, phthalates and ultraviolet (UV) filters in combination with high performance liquid chromatography-UV detection (HPLC-UV). It was found that the TiO2-nanosheets coating exhibited high extraction capability and good selectivity for some UV filters frequently used in cosmetic sunscreen formulations. The main parameters affecting extraction performance were investigated and optimized. Under the optimized conditions, the calibration graphs were linear in the range of 0.1-400μgL(-1). The limits of detection of the proposed method were between 0.026μgL(-1) and 0.089μgL(-1) (S/N=3). The single fiber repeatability varied from 4.50% to 8.76% and the fiber-to-fiber reproducibility ranged from 7.75% to 9.64% for the extraction of spiked water with 50μgL(-1) UV filters (n=5). The SPME-HPLC-UV method was successfully established for the selective preconcentration and sensitive detection of target UV filters from real environmental water samples. Recovery of UV filters spiked at 10μgL(-1) and 25μgL(-1) ranged from 88.8% to 107% and the relative standard deviations were less than 9.8%. Furthermore the in situ growth of the TiO2-nanosheets coating was performed in a highly reproducible manner and the TiO2-nanosheets coated fiber has high mechanical strength, good stability and long service life.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Éthylène glycol, ReagentPlus®, ≥99%
Sigma-Aldrich
Ammonium fluoride, ACS reagent, ≥98.0%
USP
Éthylène glycol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Pyrene, 98%
Sigma-Aldrich
Éthylène glycol, spectrophotometric grade, ≥99%
Sigma-Aldrich
Naphthalene, 99%
Sigma-Aldrich
Ammonium fluoride, ≥99.99% trace metals basis
Sigma-Aldrich
Éthylène glycol, anhydrous, 99.8%
Sigma-Aldrich
Phenanthrene, 98%
Sigma-Aldrich
Anthracene, ReagentPlus®, 99%
Sigma-Aldrich
Anthracene, reagent grade, 97%
Sigma-Aldrich
Pyrene, puriss. p.a., for fluorescence, ≥99.0% (GC)
Supelco
Éthylène glycol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
2-Ethylhexyl salicylate, 99%
Sigma-Aldrich
Éthylène glycol, BioUltra, ≥99.5% (GC)
Sigma-Aldrich
Ethylene glycol 5 M solution
Sigma-Aldrich
Naphthalene, suitable for scintillation, ≥99%
Sigma-Aldrich
Fluoranthene, 98%
Supelco
Pyrene, analytical standard
Supelco
Phenanthrene, analytical standard, for environmental analysis
Supelco
Éthylène glycol, analytical standard
Sigma-Aldrich
Phenanthrene, sublimed grade, ≥99.5%
Supelco
Naphthalene, analytical standard
USP
Octisalate, United States Pharmacopeia (USP) Reference Standard
Supelco
Fluoranthene, analytical standard
Supelco
Octisalate, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
2-Ethylhexyl salicylate, ≥99%
Sigma-Aldrich
Anthracene, suitable for scintillation, ≥99.0% (GC)
Supelco
Ethylene glycol solution, NMR reference standard, 80% in DMSO-d6 (99.9 atom % D), NMR tube size 5 mm × 8 in.
Supelco
Anthracene, analytical standard