Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

CTGR03TP1

Millipore

Cartouche Aervent® 0,2 µm

pore size 0.2 μm, cartridge nominal length 30 in. (76 cm), Code 0 (2-222; O-rings)

Synonyme(s) :

Aervent CTGR Cartridge Filter 30 in. 0.2 µm Code 0

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
23151806
eCl@ss :
32031690

Matériaux

PTFE
polypropylene
polypropylene support
silicone seal

Niveau de qualité

Stérilité

non-sterile

Mode de stérilisation compatible

steam-in-place compatible

Gamme de produits

Aervent®

Caractéristiques

hydrophobic

Fabricant/nom de marque

Aervent®

Paramètres

≤72 mL/min nitrogen diffusion at 970 mbar (14 psig) and 23 °C (in 70/30% IPA/water)
1.7 bar max. inlet pressure (25 psi) at 80 °C
1.8 bar max. differential pressure (25 psid) at 80 °C (Forward)
4.1 bar max. differential pressure (60 psid) (Reverse; intermittent)
4.1 bar max. inlet pressure (60 psi) (Reverse; Intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)

Technique(s)

gas filtration: suitable

Longueur

30 in.

Largeur

2.7 in.

Longueur nominale des cartouches

30 in. (76 cm)

Diamètre

6.9 cm (2.7 in.)

Surface de filtration

1.95 m2

Impuretés

<0.25 EU/mL USP bacterial endotoxins (LAL test, aqueous extraction)

Extractibles par gravimétrie

≤105 mg/cartridge

Matrice

Aervent®

Dimension de pores

0.2 μm pore size

Entrée

sample type gas

Point de bulle

≥1100 mbar (16 psig), nitrogen with 70/30% IPA/water at 23 °C

Code de la cartouche

Code 0 (2-222; O-rings)

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Device Configuration: Cartridge

Caractéristiques et avantages

Rated for aerosol retention of a total challenge of 108–1010 plaque forming units of ΦX-174 virus particles at 85 Nm3/h (50 SCFM) per cartridge.

Conditionnement

Double Easy-Open bag

Qualité

Retains Brevundimonas diminuta liquid aerosol for 21 days at a minimum challenge of 10⁷ CFU/cm²

Notes préparatoires

Sterilization Method
150 (100 forward/50 reverse) SIP cycles of 30 min @ 145 °C
This product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Remarque sur l'analyse

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Gravimetric Extractables: after 24 hours in a 70/30% IPA/water mixture at controlled room temperature
HydroCorr: ≤2.3 mL/min @ 2.6 bar (38 psig) per 30 in cartridge

Autres remarques

Directions for Use
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Informations légales

AERVENT is a registered trademark of Merck KGaA, Darmstadt, Germany
ASTM is a registered trademark of American Society for Testing and Materials

Vous ne trouvez pas le bon produit ?  

Essayez notre Outil de sélection de produits.


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique