Accéder au contenu
MilliporeSigma

Technical brief: Optimized pipeline for isolation of high-quality RNA from corneal cell subpopulations.

Molecular vision (2014-06-19)
Chris Bath, Trine Fink, Henrik Vorum, Jesper Hjortdal, Vladimir Zachar
RÉSUMÉ

Attempts to determine the transcriptional profile of discrete subsets of limbal epithelial cells in situ using laser capture microdissection (LCM) face two major challenges. First, the transcriptional profile of cells within a tissue may rapidly change as the tissue is excised and exposed to cold ischemia. Second, there is a risk of degradation of the RNA as the cellular compartment is separated from the remaining tissue. An optimized protocol for LCM of corneal epithelium is presented to address these issues. Experiments using porcine eye globes were carried out to determine both optimal procedures and settings for tissue harvest, transport, storage, histology, LCM, and RNA isolation. The optimized protocol was validated using human corneal epithelium. To facilitate preservation of the gene expression profile, we have developed a mechanical tool for dissection of cornea that, in combination with flash freezing, enables tissue to be stored within 5 min of enucleation of the eye. Furthermore, we describe how RNA from limbal crypt cells may be obtained using a procedure involving cryosectioning, histological staining, and LCM. In this paper, we describe an optimized method for isolating high-quality RNA from cellular subpopulations confined to the limbal crypts of the cornea. The procedure yields RNA in amounts and quality suitable for downstream gene expression analyses, such as microarrays or next generation sequencing.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Éthanol, ACS reagent, prima fine spirit, without additive, F15 o1
Sigma-Aldrich
L-Lysine monohydrochloride, from non-animal source, meets EP, JP, USP testing specifications, suitable for cell culture, 98.5-101.0%
Sigma-Aldrich
Éthanol, purum, fine spirit, denaturated with 4.8% methanol, F25 METHYL1, ~96% (based on denaturant-free substance)
Supelco
Ethanol solution, certified reference material, 2000 μg/mL in methanol
Sigma-Aldrich
Xylazine, ≥99%
USP
Éthanol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
L-Lysine monohydrochloride, reagent grade, ≥98% (HPLC)
Supelco
Éthanol, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
L-Lysine monohydrochloride, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
L-Lysine monohydrochloride, BioUltra, ≥99.5% (AT)
Lysine hydrochloride, European Pharmacopoeia (EP) Reference Standard
Supelco
L-Lysine hydrochloride solution, 100 mM amino acid in 0.1 M HCl, analytical standard
Supelco
L-Lysine monohydrochloride, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland