Accéder au contenu
MilliporeSigma

On-fiber furan formation from volatile precursors: a critical example of artefact formation during Solid-Phase Microextraction.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2012-05-01)
An Adams, Fien Van Lancker, Bruno De Meulenaer, Agnieszka Owczarek-Fendor, Norbert De Kimpe
RÉSUMÉ

For the analysis of furan, a possible carcinogen formed during thermal treatment of food, Solid-Phase Microextraction (SPME) is a preferred and validated sampling method. However, when volatile furan precursors are adsorbed on the carboxen/PDMS fiber, additional amounts of furan can be formed on the fiber during thermal desorption, as shown here for 2-butenal and furfural. No significant increase in furan amounts was found upon heating the furan precursor 2-butenal, indicating that the furan amounts formed during precursor heating experiments are negligible as compared to the additional amounts of furan formed during fiber desorption. This artefactual furan formation increased with increasing desorption time, but especially with increasing desorption temperature. Although this effect was most pronounced on the Carboxen/PDMS SPME-fiber, it was also noted on two other SPME-fibers tested (PDMS and DVB/Carboxen/PDMS). The general impact on furan data from food and model systems in literature will depend on the amounts of volatile precursors present, but will probably remain limited. However, considering the importance of this worldwide food contaminant, special care has to be taken during SPME-analysis of furan. Especially when performing precursor studies, static headspace sampling should preferably be applied for furan analysis.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
Tube ORBO Carboxen-564, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
Adsorbant Carboxen®, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Supelco
ORBO-78 400/200 MG PK/25, W,W,W separators, O.D. × L 6 mm × 110 mm, pkg of 25 ea
Supelco
PLOT - Carboxen-1010, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Sigma-Aldrich
Crotonaldehyde, predominantly trans, ≥99%, contains 0.1-0.2% BHT as stabilizer, 1% H2O as stabilizer
Sigma-Aldrich
Crotonaldehyde, mixture of cis and trans, ratio of cis- and trans-isomers (~1:20), ≥99.5% (GC)
Supelco
PLOT - Carboxen-1006, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
PLOT - Carboxen-1010, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
Adsorbant Carboxen®, matrix Carboxen® 572, 20-45 mesh, bottle of 10 g
Supelco
PLOT - Carboxen-1006, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Tenax® TA / Carboxen® 1018, glass TD tube, preconditioned, O.D. × L 1/4 in. × 3 1/2 in., Sealed with (Swagelok® End-Fittings), pkg of 10 ea
Supelco
Carboxen® 1000 Reversible SPE Tube, 200 mg/mL, pk 30
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), for use with autosampler, needle size 23 ga, metal alloy fiber, fiber L 2 cm
Supelco
Adsorbant Carboxen®, matrix Carboxen® 1000, 40-60 mesh, bottle of 50 g
Supelco
Adsorbant Carboxen®, matrix Carboxen® 569, 20-45 mesh, bottle of 10 g
Supelco
Adsorbant Carboxen®, matrix Carboxen® 1003, 40-60 mesh, bottle of 10 g
Supelco
Tube de sorbant ORBO-93, ORBO tube I.D. × L 6 mm × 95 mm, Bed A 180 mg, Bed B 90 mg, 60/80 mesh, pkg of 25 ea
Supelco
Fibres SPME Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS), for use with autosampler, needle size 23 ga, metal alloy fiber, fiber L 1 cm