Accéder au contenu
MilliporeSigma

A quantitative thiol reactivity profiling platform to analyze redox and electrophile reactive cysteine proteomes.

Nature protocols (2020-07-22)
Ling Fu, Zongmin Li, Keke Liu, Caiping Tian, Jixiang He, Jingyang He, Fuchu He, Ping Xu, Jing Yang
RÉSUMÉ

Cysteine is unique among all protein-coding amino acids, owing to its intrinsically high nucleophilicity. The cysteinyl thiol group can be covalently modified by a broad range of redox mechanisms or by various electrophiles derived from exogenous or endogenous sources. Measuring the response of protein cysteines to redox perturbation or electrophiles is critical for understanding the underlying mechanisms involved. Activity-based protein profiling based on thiol-reactive probes has been the method of choice for such analyses. We therefore adapted this approach and developed a new chemoproteomic platform, termed 'QTRP' (quantitative thiol reactivity profiling), that relies on the ability of a commercially available thiol-reactive probe IPM (2-iodo-N-(prop-2-yn-1-yl)acetamide) to covalently label, enrich and quantify the reactive cysteinome in cells and tissues. Here, we provide a detailed and updated workflow of QTRP that includes procedures for (i) labeling of the reactive cysteinome from cell or tissue samples (e.g., control versus treatment) with IPM, (ii) processing the protein samples into tryptic peptides and tagging the probe-modified peptides with isotopically labeled azido-biotin reagents containing a photo-cleavable linker via click chemistry reaction, (iii) capturing biotin-conjugated peptides with streptavidin beads, (iv) identifying and quantifying the photo-released peptides by mass spectrometry (MS)-based shotgun proteomics and (v) interpreting MS data by a streamlined informatic pipeline using a proteomics software, pFind 3, and an automatic post-processing algorithm. We also exemplified here how to use QTRP for mining H2O2-sensitive cysteines and for determining the intrinsic reactivity of cysteines in a complex proteome. We anticipate that this protocol should find broad applications in redox biology, chemical biology and the pharmaceutical industry. The protocol for sample preparation takes 3 d, whereas MS measurements and data analyses require 75 min and <30 min, respectively, per sample.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
HEPES, ≥99.5% (titration)
Sigma-Aldrich
Catalase from bovine liver, powder, suitable for cell culture, 2,000-5,000 units/mg protein
Millipore
Filtre filet en nylon, Millipore, filter diam. 47 mm, hydrophilic
Sigma-Aldrich
DL-Cysteine, technical grade
Sigma-Aldrich
OxMet2-alkyne
Sigma-Aldrich
HMP-alkyne, ≥95%
Sigma-Aldrich
CP-alkyne, ≥95%
Sigma-Aldrich
SuTEx1-alkyne, ≥95%