Accéder au contenu
Merck
  • Evaluating the efficiency of isotope transmission for improved panel design and a comparison of the detection sensitivities of mass cytometer instruments.

Evaluating the efficiency of isotope transmission for improved panel design and a comparison of the detection sensitivities of mass cytometer instruments.

Cytometry. Part A : the journal of the International Society for Analytical Cytology (2015-02-24)
Sabine Tricot, Mickael Meyrand, Chiara Sammicheli, Jamila Elhmouzi-Younes, Aurélien Corneau, Sylvie Bertholet, Marie Malissen, Roger Le Grand, Sandra Nuti, Hervé Luche, Antonio Cosma
RÉSUMÉ

The recent introduction of mass cytometry, a technique coupling a cell introduction system generating a stream of single cells with mass spectrometry, has greatly increased the number of parameters that can be measured per single cell. As with all new technology there is a need for dissemination of standardization and quality control procedures. Here, we characterize variations in sensitivity observed across the mass range of a mass cytometer, using different lanthanide tags. We observed a five-fold difference in lanthanide detection over the mass range and demonstrated that each instrument has its own sensitivity pattern. Therefore, the selection of lanthanide combinations is a key step in the establishment of a staining panel for mass cytometry-based experiments, particularly for multicenter studies. We propose the sensitivity pattern as the basis for panel design, instrument standardization and future implementation of normalization algorithms.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Diméthylsulfoxyde, Hybri-Max, sterile-filtered, BioReagent, suitable for hybridoma, ≥99.7%
Sigma-Aldrich
Diméthylsulfoxyde, ACS reagent, ≥99.9%
Sigma-Aldrich
Diméthylsulfoxyde, for molecular biology
Sigma-Aldrich
Diméthylsulfoxyde, suitable for HPLC, ≥99.7%
Sigma-Aldrich
Diméthylsulfoxyde, sterile-filtered, BioPerformance Certified, meets EP, USP testing specifications, suitable for hybridoma
Sigma-Aldrich
Diméthylsulfoxyde, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Diméthylsulfoxyde, ≥99.5% (GC), suitable for plant cell culture
Sigma-Aldrich
Diméthylsulfoxyde, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
Diméthylsulfoxyde, PCR Reagent
Sigma-Aldrich
Diméthylsulfoxyde, meets EP testing specifications, meets USP testing specifications
USP
Diméthylsulfoxyde, United States Pharmacopeia (USP) Reference Standard
Supelco
Diméthylsulfoxyde, analytical standard
Supelco
Diméthylsulfoxyde, for inorganic trace analysis, ≥99.99995% (metals basis)
Sigma-Aldrich
Dysprosium, ingot, 99.9% trace rare earth metals basis
Sigma-Aldrich
8-Octanoyloxypyrene-1,3,6-trisulfonic acid trisodium salt, suitable for fluorescence, ≥90% (HPCE)
Sigma-Aldrich
Dysprosium, chips, 99.9% trace rare earth metals basis
Diméthylsulfoxyde, European Pharmacopoeia (EP) Reference Standard
Dysprosium, powder, 5g, max. particle size 500 micron, 99.9%
Dysprosium, powder, 1g, max. particle size 500 micron, 99.9%
Dysprosium, powder, 10g, max. particle size 500 micron, 99.9%
Dysprosium, foil, 25x25mm, thickness 0.25mm, as rolled, 99%
Dysprosium, foil, 50x50mm, thickness 0.1mm, as rolled, 99%
Dysprosium, foil, 50x50mm, thickness 0.125mm, as rolled, 99%
Dysprosium, foil, 25x25mm, thickness 0.125mm, as rolled, 99%
Dysprosium, foil, not light tested, 25x25mm, thickness 0.005mm, as rolled, 99%
Dysprosium, foil, not light tested, 25x25mm, thickness 0.025mm, as rolled, 99.9%
Dysprosium, foil, 50x50mm, thickness 0.25mm, as rolled, 99%
Dysprosium, foil, not light tested, 5x5mm, thickness 0.005mm, as rolled, 99%
Dysprosium, rod, 50mm, diameter 6.35mm, cast, 99%
Dysprosium, rod, 100mm, diameter 6.35mm, cast, 99%