Accéder au contenu
Merck
  • Determination of the maleic acid in rat urine and serum samples by isotope dilution-liquid chromatography-tandem mass spectrometry with on-line solid phase extraction.

Determination of the maleic acid in rat urine and serum samples by isotope dilution-liquid chromatography-tandem mass spectrometry with on-line solid phase extraction.

Talanta (2015-02-24)
Hsin-Chang Chen, Charlene Wu, Kuen-Yuh Wu
RÉSUMÉ

A rapid and simple on-line solid-phase extraction coupled with isotope dilution-liquid chromatography-tandem mass spectrometry (SPE-ID-LC-MS/MS) method was developed to quantitate maleic acid in serum and urine of SpragueDawley (SD) rats. The aforementioned biological samples were spiked with (13)C2-maleic acid, vigorously vortexed, added with acetonitrile to precipitate proteins, and then injected into the on-line SPE-LC-MS/MS system for quantification. Upon validation, this method demonstrated excellent feasibility and sensitivity: calibration curves for maleic acid in serum and urine display excellent linearity with the coefficient of determination (R(2)) greater than 0.999; the limits of detection and quantitation (LOD and LOQ) for maleic acid were determined at 0.2 and 0.5μg L(-1), respectively. Additionally, intra-day accuracy for maleic acid in serum and urine samples ranged from 94.0% to 100.2% and 101.3% to 104.4%, respectively. Furthermore, inter-day accuracy ranged from 93.6% to 101.0% and from 102.3% to 111.4% in serum and urine samples, respectively. Intra-day precision %RSD of maleic acid in serum and urine samples was 13.8% or less, whereas the inter-day precision was 6.1% or less. The matrix effects were not found to be statistically significant (p=0.9145 and p=0.5378, correspondingly) based on the calculations of recovery functions. The collected serum and urine samples were analyzed using SPE-ID-LC-MS/MS. Our results reveal trace levels of maleic acid in the control rats, demonstrating that this method is capable of analyzing background levels of contaminants in biofluids with excellent sensitivity and specificity at part-per-billion levels concentrations in complex matrices.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acétonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acétonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acétate d′ammonium, ACS reagent, ≥97%
Sigma-Aldrich
Acétonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acétate d′ammonium, ≥99.99% trace metals basis
Sigma-Aldrich
Acétonitrile, suitable for HPLC, gradient grade, ≥99.9%
Supelco
Acétate d′ammonium, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
Acétate d′ammonium, for molecular biology, ≥98%
Sigma-Aldrich
Acétate d′ammonium solution, for molecular biology, 7.5 M
Sigma-Aldrich
Acétonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acide maléique, ReagentPlus®, ≥99% (HPLC)
Sigma-Aldrich
Acétate d′ammonium, 99.999% trace metals basis
Sigma-Aldrich
Acétate d′ammonium, reagent grade, ≥98%
USP
Acide maléique, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acétonitrile, ReagentPlus®, 99%
Supelco
Acide maléique, Standard for quantitative NMR, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Sigma-Aldrich
Acétonitrile, electronic grade, 99.999% trace metals basis
Supelco
Acétonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acétonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
Acétate d′ammonium solution, BioUltra, for molecular biology, ~5 M in H2O
Supelco
Acide maléique, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acétate d′ammonium, BioXtra, ≥98%
Sigma-Aldrich
Acétate d′ammonium, BioUltra, for molecular biology, ≥99.0%
Supelco
Acétonitrile, analytical standard
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Supelco
Acétonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Acétonitrile