MPVL10CL3
Durapore® 0,1 µm, Capsule Millipak®
filtration area 500 cm2, matrix Durapore®
Synonyme(s) :
Gamma Compatible Millipak -100 Filter Unit 0.1 μm 1-1/2 in. TC/TC
About This Item
Produits recommandés
Matériaux
PVDF
PVDF vent cap
polycarbonate
polycarbonate support
Niveau de qualité
Stérilité
irradiated
non-sterile
Mode de stérilisation compatible
gamma compatible
gamma compatible
Gamme de produits
Millipak®
Caractéristiques
gamma compatible
hydrophilic
Fabricant/nom de marque
Millipak®
Paramètres
0.35 bar max. differential pressure (5 psid) at 123 °C (Forward)
0.7 bar max. differential pressure (10 psid) at 25 °C (Reverse)
1.7 bar max. differential pressure (25 psid) at 80 °C (Forward)
3.8 L/min flow rate at 2.45 bar (ΔP)
4.1 bar max. differential pressure (60 psid) at 25 °C (Forward)
5.2 bar max. inlet pressure (75 psi) at 25 °C
50 L process volume
Technique(s)
sterile filtration: suitable
Longueur
5.1 in.
Largeur
3.0 in.
Diamètre
7.6 cm (3.0 in.)
Surface de filtration
500 cm2
Diam. du raccord d'entrée
1.5 in.
Diam. du raccord de sortie
1.5 in.
Impuretés
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Extractibles par gravimétrie
≤2.5 mg/device
Matrice
Durapore®
Dimension de pores
0.1 μm
Point de bulle
≥4830 mbar (70 psig), air with water at 23 °C
Raccords
inlet sanitary flange
outlet sanitary flange
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
Description générale
Conditionnement
Autres remarques
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Notes préparatoires
3 autoclave cycles of 90 min @ 123°C; not in-line steam sterilizable
Remarque sur l'analyse
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Informations légales
Not finding the right product?
Try our Outil de sélection de produits.
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique