  • Impurity profiling and a stability-indicating UPLC method development and validation for the estimation of related impurities of halobetasol propionate in halobetasol propionate 0.05% (w/w) cream.

Impurity profiling and a stability-indicating UPLC method development and validation for the estimation of related impurities of halobetasol propionate in halobetasol propionate 0.05% (w/w) cream.

Journal of chromatographic science (2014-05-06)
Lakkireddy Prakash, H Malipeddi, B Venkata Subbaiah, Narasimha S Lakka
ABSTRACT

A simple, short and stability-indicating reverse phase-ultra-performance liquid chromatography method was developed and validated for the quantitative determination of related impurities of halobetasol propionate in halobetasol propionate 0.05% cream formulation. The proposed method was developed on an ACQUITY UPLC™ BEH Phenyl (2.1 × 100 mm, 1.7 µm) column at 40°C with a mobile phase containing a gradient mixture of potassium hydrogen phosphate buffer and acetonitrile and methanol as modifiers with a runtime of 13.0 min at a monitored wavelength of 242 nm. A simple preparative method and liquid chromatography-mass spectrometry-compatible UPLC method also were developed for the isolation and identification of impurities and degradation products. The drug was subjected to forced-degradation conditions and found to degrade significantly. The stability-indicating capability of the developed method is established by analyzing forced-degradation samples in which the spectral purity of halobetasol propionate is ascertained along with the separation of degradation products from the analyte peak. The developed method was validated as per International Conference on Harmonization guidelines. The developed method is precise (%relative standard deviation <2.0) and is capable of detecting and quantifying all the six impurities at a level of 0.01 and 0.03%, respectively, with respect to test concentration. The wide linearity range, sensitivity, accuracy, short retention time and simple mobile phase imply that the method is suitable for routine quantification of halobetasol propionate and its related substances.

MATERIALS
Product Number
Brand
Product Description

Supelco
Tetrahydrofuran, analytical standard
Supelco
Tetrahydrofuran, Selectophore, ≥99.5%
Sigma-Aldrich
Phosphoric acid solution, NMR reference standard, 85% in D2O (99.9 atom % D), NMR tube size 4.2 mm × 8 in. , WGS-5BL Coaxial NMR tube
Sigma-Aldrich
Phosphoric acid solution, 85 wt. % in H2O, FCC, FG
Sigma-Aldrich
Phosphoric acid solution, NMR reference standard, 85% in D2O (99.9 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Phosphoric acid solution, NMR reference standard, 85% in D2O (99.9 atom % D), NMR tube size 5 mm × 8 in.
Sigma-Aldrich
Methanol, NMR reference standard
Supelco
Residual Solvent - Acetonitrile, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, Absolute - Acetone free
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Tetrahydrofuran, contains 250 ppm BHT as inhibitor, ACS reagent, ≥99.0%
Sigma-Aldrich
Tetrahydrofuran, ACS reagent, ≥99.0%, contains 250 ppm BHT as inhibitor
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Supelco
Tetrahydrofuran, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Tetrahydrofuran, inhibitor-free, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Potassium phosphate monobasic, 99.99% trace metals basis
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Sigma-Aldrich
Phosphoric acid-16O4 solution, 70 wt. % in D2O, 99.9 atom % 16O
Sigma-Aldrich
Potassium phosphate monobasic, BioUltra, for molecular biology, anhydrous, ≥99.5% (T)
Sigma-Aldrich
Potassium phosphate monobasic, tested according to Ph. Eur., anhydrous
Supelco
Trifluoroacetic acid, analytical standard
Sigma-Aldrich
Phosphoric acid, BioUltra, ≥85% (T)