Direkt zum Inhalt
Merck
  • Determination of chlorobenzenes in water samples by solid-phase disk extraction and gas chromatography-electron capture detection.

Determination of chlorobenzenes in water samples by solid-phase disk extraction and gas chromatography-electron capture detection.

Journal of chromatographic science (2013-05-07)
Hongmei Hu, Yuanming Guo, Xiumei Sun, Xuechang Chen, Xiaoning Zhang, Qin Liu, Chunxiu Xu
ZUSAMMENFASSUNG

A simple, rapid, sensitive and high throughput method is described, based on solid-phase disk extraction (SPDE) and gas chromatography-electron capture detection, for the determination of chlorobenzens (CBs) in water samples. The proposed SPDE sample pretreatment method was initially optimized and the optimum experimental conditions were found to be as follows: 500 mL water sample (pH 2.5) extracted and enriched by an Empore 3-stn C18 (octadecyl) SPE disk at flow rate of 5 to 50 mL/min, eluted by 5 mL of acetone and 3 × 5 mL of methylene dichloride. The linearity of the method ranged from 0.02 to 0.4 µg/L for dichlorobenzene isomers, 0.0022-0.044 µg/L for trichlorobenzene isomers, 0.005-0.01 µg/L for tetrachlorobenzene isomers and 0.00025 to 0.005 µg/L for pentachlorobenzenes and hexachlorobenzenes, with correlation coefficients ranging between 0.9991 and 0.9999. The limits of detection were in the low ng/L level, ranging between 0.05 and 4 ng/L. The recoveries of spiked CBs with the external calibration method at different concentration levels in deionized/distilled water, tap water and sea water samples were 99-115, 91-106% and 96-110%, respectively, and with relative standard deviations of 4.5-7.6, 4.2-6.8 and 3.6-6.6% (n = 5), respectively. It is concluded that this method can successfully be applied for the determination of CBs in deionized/distilled water, tap water and sea water samples.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Natriumchlorid, for molecular biology, DNase, RNase, and protease, none detected, ≥99% (titration)
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Natriumchlorid -Lösung, 5 M in H2O, BioReagent, for molecular biology, suitable for cell culture
Sigma-Aldrich
Natriumchlorid -Lösung, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
Natriumchlorid, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%
Sigma-Aldrich
1,2,4-Trichlorbenzol, suitable for HPLC, ≥99%
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Natriumchlorid, BioXtra, ≥99.5% (AT)
Sigma-Aldrich
Methanol, BioReagent, ≥99.93%
Sigma-Aldrich
Methanol, Absolute - Acetone free
SAFC
Natriumchlorid -Lösung, 5 M
Sigma-Aldrich
Methanol, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Chlorbenzol, ACS reagent, ≥99.5%
Sigma-Aldrich
Chlorbenzol, anhydrous, 99.8%
Sigma-Aldrich
Natriumchlorid -Lösung, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
USP
Methylalkohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Natriumchlorid, BioUltra, for molecular biology, ≥99.5% (AT)
Sigma-Aldrich
Chlorbenzol, suitable for HPLC, 99.9%
Sigma-Aldrich
Natriumchlorid, 99.999% trace metals basis
Sigma-Aldrich
Natriumchlorid -Lösung, 5 M
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Natriumchlorid, meets analytical specification of Ph. Eur., BP, USP, 99.0-100.5%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
1,2,4-Trichlorbenzol, ReagentPlus®, ≥99%
Supelco
Methanol, analytical standard