GE28-9466-03

HiTrap® Albumin IgG Depletion

Cytiva 28-9466-03, pack of 2 × 1 mL

Synonym(e):

Albumin depletion column, Albumin removal column

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
41105323
NACRES:
NA.56

Preise und Verfügbarkeit sind derzeit nicht verfügbar.

ligand

recombinant protein G fragment and recombinant protein binding HSA

Leistungsmerkmale

wetted part: no

Verpackung

pack of 2 × 1 mL

Hersteller/Markenname

Cytiva 28-9466-03

Lagerbedingungen

(20% Ethanol)

Bettgröße

7 mm × 25 mm

Bettvolumen

1 mL

Säule ID

7 mm

Durchschnittliche Teilgröße

34 μm

cleaning

2-9

Allgemeine Beschreibung

HiTrap® Albumin & IgG Depletion is prepacked columns for the depletion of albumin and IgG from human serum and plasma. The columns are prepacked with high performance SepharoseTM based media with an affinity for human serum albumin (HSA) and IgG.

Anwendung

HiTrap® Albumin & IgG Depletion and Albumin & IgG Depletion SpinTrap are prepacked columns for the depletion of albumin and IgG from plasma and serum samples. Albumin and IgG are the most abundant plasma Proteins, and they tend to obscure the signals of less abundant Proteins. Depletion of the two Proteins removes more than 60% of the total Protein content in human plasma, allowing a higher load of less abundant Proteins to be included in the analysis and detection of more Proteins. These columns are members of the Trap platform and address the need for flexible, small-scale preparation of Protein samples prior to downstream analyses such as 1-D or 2-D gel electrophoresis and mass spectrometry.

Leistungsmerkmale und Vorteile

  • HiTrap® Albumin & IgG Depletion is a prepacked column for the depletion of albumin and IgG from human serum or plasma.
  • HiTrap® Albumin & IgG Depletion column provides rapid and easy processing in a convenient format for handling larger sample volumes (~150 μL) using a liquid chromatography system or manually using a syringe.
  • Columns are prepacked with high performance Sepharose based media with an affinity for human serum albumin (HSA) and IgG.
  • High depletion capacity, removes > 95% HSA and > 90% IgG, with high reproducibility.
  • Simple and fast procedure.
  • Removal of albumin and IgG allows a higher load of less abundant Proteins to be included in the analysis and detection of more Proteins.

Lagerung und Haltbarkeit

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

Hinweis zur Analyse

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Sonstige Hinweise

The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.

Rechtliche Hinweise

HiTrap is a registered trademark of Cytiva
Sepharose is a trademark of Cytiva
SpinTrap is a trademark of Cytiva

Piktogramme

Flame

Signalwort

Warning

H-Sätze

Lagerklassenschlüssel

3 - Flammable liquids


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Dokumente section.

Wenn Sie Hilfe benötigen, wenden Sie sich bitte an Kundensupport

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

Slide 1 of 1

1 of 1

Protokolle

This page shows how to purify or remove albumin and IgG with Albumin & IgG Depletion Sepharose High Performance from Cytiva.

This page covers detailed information on cleaning procedures and recommended flow for column cleaning.

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.