Skip to Content
MilliporeSigma

Skip To

FMLW04700

PTFE Membrane Filter, 5.0 μm Pore Size

greener alternative

Fluoropore®, filter diam. 47 mm, hydrophobic

Synonym(s):

Fluoropore Membrane Filter

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
100 filters
Check Cart for Availability
$959.00

About This Item

UNSPSC Code:
40161507
NACRES:
NB.24
eCl@ss:
32031602
Pore size:
5.0 μm pore size, 85 % porosity
Material:
PTFE membrane, gridded filter, white filter
Feature:
hydrophobic
Diam.:
47 mm
Sterility:
non-sterile

$959.00


Check Cart for Availability
Get a compatible glass filter holder. Try XX1014700

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


material

PTFE membrane, gridded filter, white filter

sterility

non-sterile

feature

hydrophobic

manufacturer/tradename

Fluoropore®, Millipore

sustainability

Greener Alternative Product

parameter

122 mL/min-cm2 water flow rate, 130 °C max. temp., 6 L/min-cm2 air flow rate

diam.

47 mm

filter diam.

47 mm

thickness

150 μm

matrix

Fluoropore®

pore size

5.0 μm pore size, 85 % porosity

bubble point

≥0.48 bar, air with water at 23 °C

greener alternative category

shipped in

ambient

General description

Filter Code: FMLW
Unlike fibrous filter media that trap particles in their matrix, Fluoropore® (hydrophobic PTFE) membranes collect particles on their surface, which make them ideal candidates for use in airborne particle monitoring applications. This surface collection provides better detection efficiencies and lower FWHM measurements. (FWHM is defined as the full width at half of the maximum height of the P0-218 peak obtained during sampling of room air.)

•High collection efficiency
•Extremely low pressure drop
•Higher throughput capacity
•Black backing ensures proper orientation

Choice of Pore Sizes:
Fluoropore membranes are available in 3 µm (FSLW) and 5 µm (FMLW) pore sizes - the smaller pore size provides low FWHM; the larger pore size has very low pressure drop and greater throughput capacity, which minimizes the number of filter changeouts.

Contrasting Backing Material:
The white backing of our FMLW filter is gridded to assist in identifying membrane orientation for the correct installation into sampling devices.
We are committed to bringing you Greener Alternative Products, which have been re-engineered to enable more sustainable research solutions. The inner & outer boxes containing the membrane discs are made from bio-circular material allocated using the ISCC mass balance approach. Click here for more information.
Need a custom membrane filter? Click here to request a custom membrane filter or unique and large package sizes that may not be available via our website.

Application

  • Clarifying acids, bases, and solvents
  • Filtering or venting gases
  • UV spectroscopy
  • Particle monitoring
  • HPLC, UPLC, LC-MS/MS mobile phase filtration
  • Microplastics analysis

Legal Information

Fluoropore is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
FALP09050FHLP04700FALP14250
diam.

47 mm

diam.

90 mm

diam.

47 mm

diam.

142 mm

material

PTFE membrane, white filter, gridded filter

material

PTFE membrane, plain filter, white filter

material

PTFE membrane, plain filter, white filter

material

PTFE membrane, plain filter, white filter

pore size

5.0 μm pore size, 85 % porosity

pore size

1.0 μm pore size, ≥65 % porosity

pore size

0.45 μm pore size, >60 % porosity

pore size

1.0 μm pore size, ≥65 % porosity

parameter

122 mL/min-cm2 water flow rate, 6 L/min-cm2 air flow rate, 130 °C max. temp.

parameter

≥150 mL/min-cm2 flow rate (27.5inHg, methanol), ≥300 mL/min-cm2 air flow rate (Gurley), 130 °C max. temp. (Curling observed at elevated temperatures)

parameter

≥60 mL/min-cm2 flow rate (27.5 inHg, methanol), >0.5 L/min-cm2 air flow rate (Gurley), 100 °C max. temp. (Curling may occur at elevated temperatures)

parameter

≥150 mL/min-cm2 flow rate (27.5 inHg, methanol), ≥300 mL/min-cm2 air flow rate (Gurley), 130 °C max. temp. (Curling observed at elevated temperatures)

manufacturer/tradename

Fluoropore®, Millipore

manufacturer/tradename

Fluoropore®, Millipore

manufacturer/tradename

Fluoropore®, Millipore

manufacturer/tradename

Fluoropore®, Millipore

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile


Still not finding the right product?


Storage Class

10-13 - German Storage Class 10 to 13



Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. What is the reason for the difference in air flow rate between the FSLW04700 Millipore Fluoropore with a 3.0 µm pore size and the FMLW04700 Millipore Fluoropore with a 5.0 µm pore size, both made of hydrophobic PTFE and 47 mm membrane?

    1 answer
    1. The relationship between flow rate and pressure drop is such that the lower the flow rate, the lower the pressure drop. Fluoropore membranes come in 3 and 5 µm pore sizes. The smaller pore size offers low FWHM, while the larger pore size results in very low pressure drop and greater throughput capacity, thereby minimizing the number of filter changeouts.

      *FWHM refers to the full width at half of the maximum height of the P0-218 peak obtained during sampling of room air.

      Helpful?

  2. Why is the backing of the FMLW04700 5.0 um PTFE 47mm disc gridded? Additionally, what is the reason for the gridded backing on FMLW03700, FMLW02500, SA1J014I14, and SA1J006I15, which are also "FMLW" discs with different diameters?

    1 answer
    1. The FMLW04700 5 um PTFE membrane with a white gridded backing is designed for air alpha monitoring of radioactive particles. In this application, the filter membrane must be oriented in the alpha monitoring instrument so that the PTFE side faces the air flow. The gridded backing serves the purpose of making it easy to distinguish between the two sides. The backing is necessary because the PTFE membrane alone can be floppy and difficult to handle, particularly in field testing scenarios.

      Helpful?

Reviews

No rating value