Saltar al contenido
Merck
  • Determination of chloramphenicol, thiamphenicol, florfenicol, and florfenicol amine in poultry and porcine muscle and liver by gas chromatography-negative chemical ionization mass spectrometry.

Determination of chloramphenicol, thiamphenicol, florfenicol, and florfenicol amine in poultry and porcine muscle and liver by gas chromatography-negative chemical ionization mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2009-04-28)
Jianzhong Shen, Xi Xia, Haiyang Jiang, Cun Li, Jiancheng Li, Xiaowei Li, Shuangyang Ding
RESUMEN

A sensitive and reliable method using gas chromatography-negative chemical ionization mass spectrometry (GC-NCI/MS) was developed for the simultaneous determination of chloramphenicol (CAP), thiamphenicol (TAP), florfenicol (FF), and florfenicol amine (FFA) at trace levels in muscle and liver. Before extraction with ethyl acetate, CAP-d(5) was added to tissue samples as internal standard. The organic extracts were frozen to remove lipid and further purified by liquid-liquid extraction (LLE) with hexane and solid-phase extraction (SPE) using Oasis HLB cartridges. The target compounds were derivatized with BSTFA+1% TMCS prior to GC-NCI/MS determination in selected ion monitoring mode (SIM). The recovery values ranged from 78.5 to 105.5%, with relative standard deviations (RSD) <17%. The limits of detections (LODs) of 0.1 microg/kg for CAP and 0.5 microg/kg for TAP, FF, and FFA were obtain. Incurred sample and samples from local market were successfully analyzed using this method.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Supelco
Florfenicol amine, VETRANAL®, analytical standard