2-Methyl-2-butanol

ReagentPlus®, ≥99%

Synonym(s):

tert-Amyl alcohol, tert-Pentyl alcohol

Sign Into View Organizational & Contract Pricing

Select a Size

5 ML
$79.40
100 ML
$110.00

$79.40


In StockDetails


Request a Bulk Order

Select a Size

Change View
5 ML
$79.40
100 ML
$110.00

About This Item

Linear Formula:
CH3CH2C(CH3)2OH
CAS Number:
Molecular Weight:
88.15
Beilstein/REAXYS Number:
1361351
EC Number:
MDL number:
UNSPSC Code:
12352100
PubChem Substance ID:
NACRES:
NA.21
grade:
reagent
assay:
≥99%
bp:
102 °C (lit.)
vapor pressure:
12 mmHg ( 20 °C)

$79.40


In StockDetails


Request a Bulk Order

grade

reagent

Quality Level

vapor density

3 (vs air)

vapor pressure

12 mmHg ( 20 °C)

product line

ReagentPlus®

assay

≥99%

form

liquid

autoignition temp.

819 °F

expl. lim.

9 %

dilution

(for general lab use)

refractive index

n20/D 1.405 (lit.)

bp

102 °C (lit.)

mp

−12 °C (lit.)

density

0.805 g/mL at 25 °C (lit.)

functional group

hydroxyl

SMILES string

CCC(C)(C)O

InChI

1S/C5H12O/c1-4-5(2,3)6/h6H,4H2,1-3H3

InChI key

MSXVEPNJUHWQHW-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

General description

2-Methyl-2-butanol is a sterically hindered alcohol.

Application

2-Methyl-2-butanol may be used as a solvent in the following processes:
  • Palladium (II)-catalyzed ortho-C–H olefination of phenylacetic acids.[1]
  • Rhodium-catalyzed direct C-H functionalization at the C7 position of N-pivaloylindoles.[2]

It may also be used in the preparation of 2-chloro-2-methylbutane by reacting with concentrated hydrochloric acid.[3]

Legal Information

ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany

signalword

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Eye Dam. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Central nervous system, Respiratory system

Storage Class

3 - Flammable liquids

wgk_germany

WGK 1

flash_point_f

68.9 °F - closed cup

flash_point_c

20.5 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Rhodium?Catalyzed Regioselective C7?Functionalization of N?Pivaloylindoles.
Xu L, et al.
Angewandte Chemie (International Edition in English), 55(1), 321-325 (2016)
?-tert-alkylation of ketones: 2-tert-pentylcyclopentanone
Organic Syntheses, 62, 95-95 (1984)
Ternary and Binary LLE Measurements for Solvent (4-Methyl-2-pentanone and 2-Methyl-2-butanol)+ Furfural+ Water between 298 and 401K.
Ma?nnisto? M, et al.
Journal of Chemical and Engineering Data, 61(2), 903-911 (2016)
Molecular association and dynamics in n-pentanol and 2-methyl-2-butanol: Ultrasonic, dielectric and viscosity studies at various temperatures.
D'Aprano A, et al.
Molecular Physics, 55(2), 475-488 (1985)
Ligand--Accelerated ortho--C-H Olefination of Phenylacetic Acids.
Engle KM, et al.
Organic Syntheses, 92, 58-75 (2015)

Questions

1–2 of 2 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service